Linux runtime: overrun detection for real-time timers and for plc execution.
If real-time timer wakes-up PLC thread too late (10% over period), then
warning is logged.
If PLC code (IO retreive, execution, IO publish) takes longer than requested
PLC execution cycle, then warning is logged, and CPU hoogging is mitigated
by delaying next PLC execution a few cylces more until having at least
1ms minimal idle time.
from __future__ import absolute_import
from etherlab.etherlab import *
from util.BitmapLibrary import AddBitmapFolder
import util.paths as paths
AddBitmapFolder(os.path.join(paths.AbsDir(__file__), "images"))