--- a/BeremizIDE.py Thu Aug 17 10:04:24 2017 +0300
+++ b/BeremizIDE.py Thu Aug 17 10:08:23 2017 +0300
@@ -1145,15 +1145,15 @@
ignored_exceptions = [] # a problem with a line in a module is only reported once per session
-def AddExceptHook(path, app_version='[No version]'): #, ignored_exceptions=[]):
+def AddExceptHook(path, app_version='[No version]'):
def save_bug_report(e_type, e_value, e_traceback, bug_report_path, date):
info = {
- 'app-title': wx.GetApp().GetAppName(), # app_title
+ 'app-title': wx.GetApp().GetAppName(),
'app-version': app_version,
'wx-version': wx.VERSION_STRING,
'wx-platform': wx.Platform,
- 'python-version': platform.python_version(), # sys.version.split()[0],
+ 'python-version': platform.python_version(),
'platform': platform.platform(),
'e-type': e_type,
'e-value': e_value,
--- a/ConfigTreeNode.py Thu Aug 17 10:04:24 2017 +0300
+++ b/ConfigTreeNode.py Thu Aug 17 10:08:23 2017 +0300
@@ -561,7 +561,7 @@
# check name is unique
NewCTNName = _self.FindNewName(CTNName)
# If dir have already be made, and file exist
- if os.path.isdir(_self.CTNPath(NewCTNName)): #and os.path.isfile(_self.ConfNodeXmlFilePath(CTNName)):
+ if os.path.isdir(_self.CTNPath(NewCTNName)): # and os.path.isfile(_self.ConfNodeXmlFilePath(CTNName)):
# Load the confnode.xml file into parameters members
_self.LoadXMLParams(NewCTNName)
# Basic check. Better to fail immediately.
--- a/PLCOpenEditor.py Thu Aug 17 10:04:24 2017 +0300
+++ b/PLCOpenEditor.py Thu Aug 17 10:08:23 2017 +0300
@@ -463,7 +463,7 @@
ignored_exceptions = [] # a problem with a line in a module is only reported once per session
-def AddExceptHook(path, app_version='[No version]'): #, ignored_exceptions=[]):
+def AddExceptHook(path, app_version='[No version]'):
def handle_exception(e_type, e_value, e_traceback):
traceback.print_exception(e_type, e_value, e_traceback) # this is very helpful when there's an exception in the rest of this func
@@ -476,11 +476,11 @@
if result:
ignored_exceptions.append(ex)
info = {
- 'app-title': wx.GetApp().GetAppName(), # app_title
+ 'app-title': wx.GetApp().GetAppName(),
'app-version': app_version,
'wx-version': wx.VERSION_STRING,
'wx-platform': wx.Platform,
- 'python-version': platform.python_version(), #sys.version.split()[0],
+ 'python-version': platform.python_version(),
'platform': platform.platform(),
'e-type': e_type,
'e-value': e_value,
--- a/ProjectController.py Thu Aug 17 10:04:24 2017 +0300
+++ b/ProjectController.py Thu Aug 17 10:08:23 2017 +0300
@@ -1588,7 +1588,7 @@
self.TracedIECPath,
self.DebugValuesBuffers,
debug_vars):
- IECdebug_data = self.IECdebug_datas.get(IECPath, None) #FIXME get
+ IECdebug_data = self.IECdebug_datas.get(IECPath, None) # FIXME get
if IECdebug_data is not None and value is not None:
forced = IECdebug_data[2:4] == ["Forced", value]
if not IECdebug_data[4] and len(values_buffer) > 0:
--- a/controls/VariablePanel.py Thu Aug 17 10:04:24 2017 +0300
+++ b/controls/VariablePanel.py Thu Aug 17 10:08:23 2017 +0300
@@ -75,7 +75,7 @@
return {_("All"): _("All"), _("Interface"): _("Interface"),
_(" Input"): _("Input"), _(" Output"): _("Output"), _(" InOut"): _("InOut"),
_(" External"): _("External"), _("Variables"): _("Variables"), _(" Local"): _("Local"),
- _(" Temp"): _("Temp"), _("Global"): _("Global")} #, _("Access") : _("Access")}
+ _(" Temp"): _("Temp"), _("Global"): _("Global")} # , _("Access") : _("Access")}
VARIABLE_CHOICES_DICT = dict([(_(_class), _class) for _class in GetFilterChoiceTransfer().iterkeys()])
@@ -505,11 +505,11 @@
self.Table = VariableTable(self, [], GetVariableTableColnames(True))
if element_type in ["config", "resource"]:
- self.FilterChoices = ["All", "Global"] #,"Access"]
+ self.FilterChoices = ["All", "Global"] # ,"Access"]
else:
self.FilterChoices = ["All",
"Interface", " Input", " Output", " InOut", " External",
- "Variables", " Local", " Temp"] #,"Access"]
+ "Variables", " Local", " Temp"] # ,"Access"]
# these condense the ColAlignements list
left = wx.ALIGN_LEFT
--- a/runtime/PLCObject.py Thu Aug 17 10:04:24 2017 +0300
+++ b/runtime/PLCObject.py Thu Aug 17 10:08:23 2017 +0300
@@ -215,7 +215,7 @@
self._LogMessage.restype = ctypes.c_int
self._LogMessage.argtypes = [ctypes.c_uint8, ctypes.c_char_p, ctypes.c_uint32]
- self._log_read_buffer = ctypes.create_string_buffer(1 << 14) #16K
+ self._log_read_buffer = ctypes.create_string_buffer(1 << 14) # 16K
self._GetLogMessage = self.PLClibraryHandle.GetLogMessage
self._GetLogMessage.restype = ctypes.c_uint32
self._GetLogMessage.argtypes = [ctypes.c_uint8, ctypes.c_uint32, ctypes.c_char_p, ctypes.c_uint32, ctypes.POINTER(ctypes.c_uint32), ctypes.POINTER(ctypes.c_uint32), ctypes.POINTER(ctypes.c_uint32)]