--- a/tests/wamp/plc.xml Thu Aug 16 13:42:18 2018 +0300
+++ b/tests/wamp/plc.xml Thu Aug 16 16:29:06 2018 +0300
@@ -1,7 +1,7 @@
<?xml version='1.0' encoding='utf-8'?>
<project xmlns:ns1="http://www.plcopen.org/xml/tc6_0201" xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://www.plcopen.org/xml/tc6_0201">
<fileHeader companyName="Beremiz" productName="Beremiz" productVersion="1" creationDateTime="2015-02-05T11:44:55" contentDescription=" "/>
- <contentHeader name="WAMPTest" modificationDateTime="2015-02-18T23:59:50">
+ <contentHeader name="WAMPTest" modificationDateTime="2018-08-16T16:14:30">
<coordinateInfo>
<fbd>
<scaling x="0" y="0"/>
@@ -24,6 +24,9 @@
<type>
<DINT/>
</type>
+ <initialValue>
+ <simpleValue value="1"/>
+ </initialValue>
</variable>
</localVars>
<externalVars>
@@ -41,22 +44,22 @@
</interface>
<body>
<FBD>
- <inVariable localId="1" executionOrderId="0" height="25" width="55" negated="false">
- <position x="144" y="70"/>
+ <inVariable localId="1" executionOrderId="0" height="30" width="55" negated="false">
+ <position x="57" y="540"/>
<connectionPointOut>
- <relPosition x="55" y="12"/>
+ <relPosition x="55" y="15"/>
</connectionPointOut>
<expression>PyVar0</expression>
</inVariable>
- <block localId="3" typeName="ADD" executionOrderId="0" height="60" width="65">
- <position x="245" y="52"/>
+ <block localId="3" typeName="ADD" executionOrderId="0" height="60" width="67">
+ <position x="168" y="525"/>
<inputVariables>
<variable formalParameter="IN1">
<connectionPointIn>
<relPosition x="0" y="30"/>
<connection refLocalId="1">
- <position x="245" y="82"/>
- <position x="199" y="82"/>
+ <position x="168" y="555"/>
+ <position x="112" y="555"/>
</connection>
</connectionPointIn>
</variable>
@@ -64,10 +67,10 @@
<connectionPointIn>
<relPosition x="0" y="50"/>
<connection refLocalId="4">
- <position x="245" y="102"/>
- <position x="228" y="102"/>
- <position x="228" y="113"/>
- <position x="198" y="113"/>
+ <position x="168" y="575"/>
+ <position x="151" y="575"/>
+ <position x="151" y="595"/>
+ <position x="112" y="595"/>
</connection>
</connectionPointIn>
</variable>
@@ -76,28 +79,63 @@
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
- <relPosition x="65" y="30"/>
+ <relPosition x="67" y="30"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
- <inVariable localId="4" executionOrderId="0" height="25" width="73" negated="false">
- <position x="125" y="101"/>
+ <inVariable localId="4" executionOrderId="0" height="30" width="73" negated="false">
+ <position x="39" y="580"/>
<connectionPointOut>
- <relPosition x="73" y="12"/>
+ <relPosition x="73" y="15"/>
</connectionPointOut>
<expression>LocalVar0</expression>
</inVariable>
- <outVariable localId="2" executionOrderId="0" height="25" width="55" negated="false">
- <position x="344" y="70"/>
+ <comment localId="5" height="478" width="646">
+ <position x="23" y="10"/>
+ <content>
+ <xhtml:p><![CDATA[Communication between Beremiz and PLC runtime isn't bound to any specific protocol and could be extended by writing corresponding connector (see 'connectors' directory).
+Beremiz reference runtime implementation supports PYRO and WAMP protocols.
+This example shows how to use Web Application Messaging Protocol (WAMP).
+
+WAMP can be used to build distributed systems out of application components which are loosely coupled and communicate in real-time. No direct connection between IDE and PLC are necessary.
+
+WAMP is in a process to be published as official IETF standard. Draft specification is already available on IETF website.
+
+To use this example you need WAMP router and standalone running Beremiz_service.
+1. See README file in project's directory with detailed instructions for
+setup Crossbar.io, router for open Web Application Messaging Protocol (WAMP).
+2. Run crossbar
+3. Create service working directory and copy wampconf.json from project_files to created directory
+4. Run Beremiz_service:
+./Beremiz_service.py -x 0 <working directory>
+]]></xhtml:p>
+ </content>
+ </comment>
+ <inOutVariable localId="2" executionOrderId="0" height="30" width="55" negatedOut="false" negatedIn="false">
+ <position x="270" y="540"/>
<connectionPointIn>
- <relPosition x="0" y="12"/>
+ <relPosition x="0" y="15"/>
<connection refLocalId="3" formalParameter="OUT">
- <position x="344" y="82"/>
- <position x="310" y="82"/>
+ <position x="270" y="555"/>
+ <position x="235" y="555"/>
</connection>
</connectionPointIn>
+ <connectionPointOut>
+ <relPosition x="55" y="15"/>
+ </connectionPointOut>
<expression>PyVar1</expression>
+ </inOutVariable>
+ <outVariable localId="6" executionOrderId="0" height="30" width="55" negated="false">
+ <position x="362" y="540"/>
+ <connectionPointIn>
+ <relPosition x="0" y="15"/>
+ <connection refLocalId="2">
+ <position x="362" y="555"/>
+ <position x="325" y="555"/>
+ </connection>
+ </connectionPointIn>
+ <expression>PyVar0</expression>
</outVariable>
</FBD>
</body>