Edouard Tisserant [Wed, 05 Sep 2018 12:58:41 +0200] rev 2271
Removed useless condition in Worker.py that was allowing misfit non-serialized call when worker still not running its loop.
Edouard Tisserant [Tue, 21 Aug 2018 16:11:02 +0200] rev 2270
Refactoring. Separated PLC Object, PYRO Server and MainWorker :
- PLC Object is now a Singleton, instantiated through runtime.CreatePLCObjectSingleton(...)
- Pyro server doesn't hold any reference to PLCObject, and doesn't create it anymore
- PLC Object class doesn't inherit from Pyro.ObjBase anymore
- Pyro related code moved to runtime.PyroServer.py
- MainWorker class moved to runtime/Worker.py
- Both PLC Object and MainWorker creation happens in runtime/__init__.py
Edouard Tisserant [Thu, 16 Aug 2018 11:22:40 +0200] rev 2269
Fixed new code-generation code, that was making exception with simple variable-to-variable assignments.