Andrey Skvortsov <andrej.skvortzov@gmail.com> [Mon, 18 Apr 2016 19:08:29 +0300] rev 1480
fix issue, then it wasn't possible to remove functional blocks from
project using right click and popup menu.
The problem is that, PopupMenu was called using IDEFrame object and as
a result item in ProjectTree loosed focus and focus went to IDEFrame.
Therefore later functions couldn't detect which item in ProjectTree
was selected.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Mon, 18 Apr 2016 18:59:11 +0300] rev 1479
fix many compilation warnings about static variables used by non-static functions
[CC] plc_main.c -> plc_main.o
/tmp/be/build/plc_main.c:396:40: warning: ?LogBuff? is static but used in inline function ?copy_from_log? which is not static
memcpy((char*)buf + remaining, LogBuff[level], size - remaining);
^
/tmp/be/build/plc_main.c:395:22: warning: ?LogBuff? is static but used in inline function ?copy_from_log? which is not static
memcpy(buf, &LogBuff[level][buffpos], remaining);
^
...
^
/tmp/be/build/plc_debugger.c:825:20: warning: ?retain_offset? is static but used in inline function ?BufferIterator? which is not static
Retain(retain_offset, size, real_value_p);
^
/tmp/be/build/plc_debugger.c:823:47: warning: ?retain_offset? is static but used in inline function ?BufferIterator? which is not static
unsigned int next_retain_offset = retain_offset + size;
^
^
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Mon, 18 Apr 2016 18:56:51 +0300] rev 1478
make attribute CFLAGS and LDFLAGS optional and add default empty value
Actually CFLAGS and LDFLAGS are not required and can be empty.
Without default empty value if target platform in project settings was
set to "Linux" CFLAGS and LDFLAGS was initialized with NoneType.
The result was broken build and it wasn't to save/load project with
such settings.
Traceback (most recent call last):
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 956, in _Build
if not builder.build() :
File "/home/developer/WorkData/PLC/beremiz/beremiz/targets/toolchain_gcc.py", line 96, in build
Builder_CFLAGS = ' '.join(self.getBuilderCFLAGS())
TypeError: sequence item 0: expected string, NoneType found
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Mon, 18 Apr 2016 18:51:59 +0300] rev 1477
fix issue, when structure data type with array field is created
Traceback (most recent call last):
File "editors/DataTypeEditor.py", line 669, in ElementArrayTypeFunction
self.RefreshTypeInfos()
File "editors/DataTypeEditor.py", line 761, in RefreshTypeInfos
self.Controler.SetDataTypeInfos(self.TagName, infos)
File "PLCControler.py", line 2075, in SetDataTypeInfos
array.baseType.setcontent(PLCOpenParser.CreateElement(
AttributeError: 'lxml.etree._Element' object has no attribute 'setcontent'
Andrey Skvortsov <andrej.skvortzov@gmail.com [Mon, 18 Apr 2016 18:48:15 +0300] rev 1476
fixes sometimes happened error during project compilation
Traceback (most recent call last):
File "./Beremiz.py", line 1229, in run_with_except_hook
run_old(*args, **kw)
File
"/home/developer/WorkData/PLC/beremiz/beremiz/util/ProcessLogger.py",
line 68, in run
self.endcallback(self.Proc.pid, err)
File
"/home/developer/WorkData/PLC/beremiz/beremiz/util/ProcessLogger.py",
line 169, in finish
if self.timeout: self.timeout.cancel()
AttributeError: ProcessLogger instance has no attribute 'timeout'
mjsousa [Wed, 21 Oct 2015 15:00:32 +0100] rev 1475
merge
mjsousa [Sat, 06 Dec 2014 19:31:51 +0000] rev 1474
Use '-p' command line option when running matiec (iec2c)
mjsousa [Wed, 26 Nov 2014 16:05:14 +0000] rev 1473
Add command line option '-l' when calling matiec
mjsousa [Wed, 12 Nov 2014 17:36:27 +0000] rev 1472
merge
mjsousa [Tue, 08 Jul 2014 18:01:33 +0100] rev 1471
merge