Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 08 Jun 2018 15:10:27 +0300] rev 2180
Don't use fixed width labels in WAMP and PYRO dialogs
This causes problems if labels are translated into other languages and
width wasn't enough.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 07 Jun 2018 16:58:13 +0300] rev 2179
Fix internatialization in UriLocationEditor, PYRO dialog and Modbus configurator
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 07 Jun 2018 16:53:21 +0300] rev 2178
Add copyright headers to retain implementation for GNU/Linux and Win32
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 07 Jun 2018 16:31:26 +0300] rev 2177
Drop support for wxPython 2.6 and below
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 07 Jun 2018 14:45:03 +0300] rev 2176
Autoresize UriLocationEditor dialog window
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 07 Jun 2018 14:12:18 +0300] rev 2175
Fix compilation problem in case of TARGET_LOGGING_DISABLE turned on and TARGET_DEBUG_DISABLE turned off
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 07 Jun 2018 14:04:45 +0300] rev 2174
Use the same retain implementation for Win32 targets
Currently plc_Win32_main_retain.c is exact copy of
plc_Linux_main_retain.c, because it's not possible to use symbol
links.
It'd be nice in the future to have possibility to modify targets.code.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 07 Jun 2018 13:45:35 +0300] rev 2173
Add retain basic implementation on GNU/Linux
Retain is saved in file and backup of this file is done every time.
File isn't saved on every PLC cycle to avoid high I/O load.
By default, retain is saved every second and on PLC stop/shutdown.
It's possible to override retain flush period by using CFLAGS option
in project's settings. For example, for 0.5 seconds period
use "-DFILE_RETAIN_SAVE_PERIOD_S=0.5".
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 01 Jun 2018 15:46:17 +0300] rev 2172
Add helper function GetRetainSize()
it will be useful for retain implementations.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 01 Jun 2018 12:21:37 +0300] rev 2171
use CLOCK_MONOTONIC instead of CLOCK_REALTIME for timer setup
CLOCK_REALTIME is a wall clock, that could change back and forth (user
changes system time, winter/summer time, NTP corrections and so on).
For real-time application CLOCK_MONOTONIC should be used, it doesn't
have such jumps.