tests/logging/py_ext_0@py_ext/pyfile.xml
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Mon, 30 Jul 2018 19:02:36 +0300
changeset 2255 f6a0508fa473
parent 1639 1953c268a194
permissions -rw-r--r--
Fix problem with decreasing size of StatusToolBar when tools are removed from toolbar.

StatusToolBar - toolbar with tool to build, clear, connect, ...
This problem appears only in python-wxgtk3.0. In python-wxgtk2.8 there
was not such problem.

If call StatusToolBar.SetMinSize(wx.DefaultSize), all is working, but
following warning message appears:

(Beremiz.py:15155): Gtk-WARNING **: 18:42:24.115: Negative content
width -6 (allocation 1, extents 4x3) while allocating gadget (node
toolbar, owner GtkToolbar)

To avoid that StatusToolBar.GetToolBitmapSize() is used instead of wx.DefaultSize
<?xml version='1.0' encoding='utf-8'?>
<PyFile xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
  <variables/>
  <globals>
    <xhtml:p><![CDATA[import threading, time

MyT = None
Stop = False

def StartLog():
    global MyT
    MyT=threading.Thread(target = DoLog)
    MyT.start()

def DoLog():
    global Stop
    while not Stop:
        PLCObject.LogMessage("Python side Logging (PLC is %s)"%PLCObject.PLCStatus)
        time.sleep(0.3)

def StopLog():
    global MyT,Stop
    Stop=True

_runtime_init.append(StartLog)
_runtime_cleanup.append(StopLog)
]]></xhtml:p>
  </globals>
  <init>
    <xhtml:p><![CDATA[]]></xhtml:p>
  </init>
  <cleanup>
    <xhtml:p><![CDATA[]]></xhtml:p>
  </cleanup>
  <start>
    <xhtml:p><![CDATA[]]></xhtml:p>
  </start>
  <stop>
    <xhtml:p><![CDATA[]]></xhtml:p>
  </stop>
</PyFile>