doc/manual/install.rst
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Wed, 07 Dec 2016 19:24:16 +0300
changeset 1596 f5868f866d2b
parent 811 66a8812457d6
permissions -rw-r--r--
stop PLC before unloading


This fixes segmentation fault if service was quit without stopping it.
It has happened if Beremiz service was quit using taskbar icon or by
closing Beremiz IDE (in case of autostarted local service).

In second case to trigger the bug following step has to be done:
1. Open Beremiz IDE
2. Open project, compile and connect to LOCAL:// runtime
3. Transfer and start the PLC program
4. Open other project without disconneting the PLC runtime
5. Close Beremiz IDE
Beremiz installation 
====================

Windows
-------
Download installer, install. 

Linux
-----
Pre-requisites::

    # Ubuntu/Debian :
    sudo apt-get install python-wxgtk2.8 pyro mercurial
    sudo apt-get install build-essential bison flex python-numpy python-nevow

Prepare::

    mkdir ~/Beremiz
    cd ~/Beremiz

Get Source Code::

    cd ~/Beremiz
    
    hg clone http://dev.automforge.net/beremiz
    hg clone http://dev.automforge.net/plcopeneditor
    hg clone http://dev.automforge.net/matiec

Build MatIEC compiler::

    cd ~/Beremiz/matiec
    ./configure
    make

Build CanFestival (optional):: 

    # Only needed for CANopen support. Please read CanFestival 
    # manual to choose CAN interface other than 'virtual'::

    cd ~/Beremiz
    hg clone http://dev.automforge.net/CanFestival-3
    
    cd ~/Beremiz/CanFestival-3
    ./configure --can=virtual
    make

Launch Beremiz::

    cd ~/Beremiz/beremiz
    python Beremiz.py