Added PurgePLC() method to PLCObject, to be invoked when PLC Status is broken. It clears PLC shared object an extra files and force status to Empty. Added correponding Repair button to toolbar, visible only when PLC status is broken.
#!/usr/bin/env python
# -*- coding: utf-8 -*-
#
# See COPYING.Runtime file for copyrights details.
#
from __future__ import absolute_import
from ctypes import CDLL, RTLD_GLOBAL, pointer, c_int, POINTER, c_char, create_string_buffer
def TryPreloadXenomai():
"""
Xenomai 3 (at least for version <= 3.0.6) do not handle properly dlclose
of shared objects whose dlopen did trigger xenomai_init.
As a workaround, this pre-loads xenomai libraries that need to be
initialized and call xenomai_init once for all.
Xenomai auto init of libs MUST be disabled (see --auto-init-solib in xeno-config)
"""
try:
for name in ["cobalt", "modechk", "copperplate", "alchemy"]:
globals()[name] = CDLL("lib"+name+".so", mode=RTLD_GLOBAL)
cobalt.xenomai_init(pointer(c_int(0)), pointer((POINTER(c_char)*2)(create_string_buffer("prog_name"), None)))
except Exception:
pass