tests/wamp/plc.xml
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Sun, 06 Jan 2019 03:11:39 +0300
changeset 2501 eba2bbb2dd9a
parent 2298 10cfc280927c
permissions -rw-r--r--
Make online debug optional

It could be useful for very small targets like Atmega (Arduino) and
for target bring-up there developer want to have running PLC program,
but has not implemented runtime communication yet.


TARGET_DEBUG_AND_RETAIN_DISABLE - completely disable debug and retain
functionality. Previously named TARGET_DEBUG_DISABLE.

TARGET_ONLINE_DEBUG_DISABLE - can be used to enable retain
functionality (no define TARGET_DEBUG_AND_RETAIN_DISABLE is used), but disable
online debug with corresponding RAM/FLASH overhead.

TARGET_LOGGING_DISABLE - disables logging functionality from runtime and PLC program

TARGET_EXT_SYNC_DISABLE - disables PLC program synchronization with
external events. For example, it could be used to synchronize several
PLCs that control motors for different axes.

By default all these options are off.

To test generate program for Generic target, put following files in
project files directory and run build.sh after generating PLC program.
This is very easy to integrate into makefile (Generic target).

[------------- build.sh --------------------------]
files=$(find $PWD/../build -iname '*.c' | grep -v POUS.c)
arm-none-eabi-gcc \
-DTARGET_DEBUG_AND_RETAIN_DISABLE \
-DTARGET_ONLINE_DEBUG_DISABLE \
-DTARGET_LOGGING_DISABLE \
-DTARGET_EXT_SYNC_DISABLE \
-flto -ffunction-sections -fdata-sections -I../../../../matiec/lib/C \
$files \
main.c \
-Wl,--Map=./program.map,--cref \
-nodefaultlibs --specs=nano.specs -Wl,--static -Wl,--gc-section -Wl,--start-group -lc -lm -lnosys -lgcc -Wl,--end-group
[------------------------------------------------]

[------------- main.c --------------------------]
#ifndef TARGET_DEBUG_AND_RETAIN_DISABLE
void Retain(void){}
void InValidateRetainBuffer(void){}
void ValidateRetainBuffer(void){}
#endif

extern void __run(void);
int main(void)
{
for(;;) {
__run();
// sleep common_ticktime__ ns
// add common_ticktime__ ns to __CURRENT_TIME
}
return 0;
}
[------------------------------------------------]
<?xml version='1.0' encoding='utf-8'?>
<project xmlns:ns1="http://www.plcopen.org/xml/tc6_0201" xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://www.plcopen.org/xml/tc6_0201">
  <fileHeader companyName="Beremiz" productName="Beremiz" productVersion="1" creationDateTime="2015-02-05T11:44:55" contentDescription=" &#10;&#10;"/>
  <contentHeader name="WAMPTest" modificationDateTime="2018-08-27T11:11:30">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes/>
    <pous>
      <pou name="program0" pouType="program">
        <interface>
          <localVars>
            <variable name="LocalVar0">
              <type>
                <DINT/>
              </type>
              <initialValue>
                <simpleValue value="1"/>
              </initialValue>
            </variable>
          </localVars>
          <externalVars>
            <variable name="PyVar0">
              <type>
                <DINT/>
              </type>
            </variable>
            <variable name="PyVar1">
              <type>
                <DINT/>
              </type>
            </variable>
          </externalVars>
        </interface>
        <body>
          <FBD>
            <inVariable localId="1" executionOrderId="0" height="30" width="55" negated="false">
              <position x="57" y="540"/>
              <connectionPointOut>
                <relPosition x="55" y="15"/>
              </connectionPointOut>
              <expression>PyVar0</expression>
            </inVariable>
            <block localId="3" typeName="ADD" executionOrderId="0" height="60" width="67">
              <position x="168" y="525"/>
              <inputVariables>
                <variable formalParameter="IN1">
                  <connectionPointIn>
                    <relPosition x="0" y="30"/>
                    <connection refLocalId="1">
                      <position x="168" y="555"/>
                      <position x="112" y="555"/>
                    </connection>
                  </connectionPointIn>
                </variable>
                <variable formalParameter="IN2">
                  <connectionPointIn>
                    <relPosition x="0" y="50"/>
                    <connection refLocalId="4">
                      <position x="168" y="575"/>
                      <position x="151" y="575"/>
                      <position x="151" y="595"/>
                      <position x="112" y="595"/>
                    </connection>
                  </connectionPointIn>
                </variable>
              </inputVariables>
              <inOutVariables/>
              <outputVariables>
                <variable formalParameter="OUT">
                  <connectionPointOut>
                    <relPosition x="67" y="30"/>
                  </connectionPointOut>
                </variable>
              </outputVariables>
            </block>
            <inVariable localId="4" executionOrderId="0" height="30" width="73" negated="false">
              <position x="39" y="580"/>
              <connectionPointOut>
                <relPosition x="73" y="15"/>
              </connectionPointOut>
              <expression>LocalVar0</expression>
            </inVariable>
            <comment localId="5" height="459" width="788">
              <position x="23" y="10"/>
              <content>
                <xhtml:p><![CDATA[Communication between Beremiz and PLC runtime isn't bound to any specific protocol and could be extended by writing corresponding connector (see 'connectors' directory).
Beremiz reference runtime implementation supports PYRO and WAMP protocols.
This example shows how to use Web Application Messaging Protocol (WAMP).

WAMP can be used to build distributed systems out of application components which are loosely coupled and communicate in real-time. No direct connection between IDE and PLC are necessary.

WAMP is in a process to be published as official IETF standard. Draft specification is already available on IETF website.
	
To use this example you need WAMP router and standalone running Beremiz_service.
1. See README file in project's directory with detailed instructions for
setup Crossbar.io, router for open Web Application Messaging Protocol (WAMP).
2. Run crossbar
3. Create service working directory and copy wampconf.json from project_files to created directory
4. Run Beremiz_service:
./Beremiz_service.py -x 0 <working directory>
]]></xhtml:p>
              </content>
            </comment>
            <inOutVariable localId="2" executionOrderId="0" height="30" width="55" negatedOut="false" negatedIn="false">
              <position x="270" y="540"/>
              <connectionPointIn>
                <relPosition x="0" y="15"/>
                <connection refLocalId="3" formalParameter="OUT">
                  <position x="270" y="555"/>
                  <position x="235" y="555"/>
                </connection>
              </connectionPointIn>
              <connectionPointOut>
                <relPosition x="55" y="15"/>
              </connectionPointOut>
              <expression>PyVar1</expression>
            </inOutVariable>
            <outVariable localId="6" executionOrderId="0" height="30" width="55" negated="false">
              <position x="362" y="540"/>
              <connectionPointIn>
                <relPosition x="0" y="15"/>
                <connection refLocalId="2">
                  <position x="362" y="555"/>
                  <position x="325" y="555"/>
                </connection>
              </connectionPointIn>
              <expression>PyVar0</expression>
            </outVariable>
          </FBD>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations>
      <configuration name="config">
        <resource name="resource1">
          <task name="Task0" priority="0" interval="T#100ms">
            <pouInstance name="Instance0" typeName="program0"/>
          </task>
        </resource>
      </configuration>
    </configurations>
  </instances>