targets/plc_main_head.c
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Wed, 13 Mar 2019 11:47:03 +0300
changeset 2537 eb4a4cc41914
parent 2503 6ffeffb6d635
child 3947 9b5cb90297e4
permissions -rw-r--r--
Fix various pylint and pep8 errors

Check basic code-style problems for PEP-8
pep8 version: 2.4.0
./connectors/PYRO/__init__.py:57:43: E261 at least two spaces before inline comment
./connectors/SchemeEditor.py:29:21: E128 continuation line under-indented for visual indent
./controls/IDBrowser.py:101:23: E127 continuation line over-indented for visual indent
./controls/IDBrowser.py:102:23: E127 continuation line over-indented for visual indent

Check for problems using pylint ...
No config file found, using default configuration
pylint 1.9.4,
astroid 1.6.5
Python 2.7.16rc1 (default, Feb 18 2019, 11:05:09)
[GCC 8.2.0]
Use multiple threads for pylint
Using config file /home/developer/WorkData/PLC/beremiz/beremiz/.pylint
************* Module connectors.PYRO_dialog
connectors/PYRO_dialog.py:9: [W0611(unused-import), ] Unused import wx
************* Module connectors
connectors/__init__.py:32: [W1652(deprecated-types-field), ] Accessing a deprecated fields on the types module
connectors/__init__.py:32: [C0411(wrong-import-order), ] standard import "from types import ClassType" should be placed before "from connectors.ConnectorBase import ConnectorBase"
************* Module connectors.PYRO.PSK_Adapter
connectors/PYRO/PSK_Adapter.py:7: [C0411(wrong-import-order), ] standard import "import ssl" should be placed before "import sslpsk"
************* Module connectors.SchemeEditor
connectors/SchemeEditor.py:29: [C0330(bad-continuation), ] Wrong continued indentation (add 1 space).
wx.ALIGN_CENTER_VERTICAL),
^|
connectors/SchemeEditor.py:42: [W0631(undefined-loop-variable), SchemeEditor.__init__] Using possibly undefined loop variable 'tag'
************* Module runtime.WampClient
runtime/WampClient.py:138: [W1612(unicode-builtin), WampSession.onJoin] unicode built-in referenced
runtime/WampClient.py:154: [W1612(unicode-builtin), WampSession.publishWithOwnID] unicode built-in referenced
runtime/WampClient.py:346: [W1612(unicode-builtin), PublishEvent] unicode built-in referenced
runtime/WampClient.py:351: [W1612(unicode-builtin), PublishEventWithOwnID] unicode built-in referenced
runtime/WampClient.py:31: [W0611(unused-import), ] Unused str imported from builtins as text
************* Module runtime.PLCObject
runtime/PLCObject.py:35: [W1648(bad-python3-import), ] Module moved in Python 3
runtime/PLCObject.py:35: [C0411(wrong-import-order), ] standard import "import md5" should be placed before "from six.moves import xrange"
runtime/PLCObject.py:36: [C0411(wrong-import-order), ] standard import "from tempfile import mkstemp" should be placed before "from six.moves import xrange"
runtime/PLCObject.py:37: [C0411(wrong-import-order), ] standard import "import shutil" should be placed before "from six.moves import xrange"
runtime/PLCObject.py:38: [C0411(wrong-import-order), ] standard import "from functools import wraps, partial" should be placed before "from six.moves import xrange"
************* Module runtime.Worker
runtime/Worker.py:12: [W1648(bad-python3-import), ] Module moved in Python 3
************* Module runtime.spawn_subprocess
runtime/spawn_subprocess.py:125: [C0325(superfluous-parens), ] Unnecessary parens after 'print' keyword
runtime/spawn_subprocess.py:130: [C0325(superfluous-parens), ] Unnecessary parens after 'print' keyword
runtime/spawn_subprocess.py:125: [E1601(print-statement), ] print statement used
runtime/spawn_subprocess.py:130: [E1601(print-statement), ] print statement used
************* Module controls.IDBrowser
controls/IDBrowser.py:101: [C0330(bad-continuation), ] Wrong continued indentation (remove 5 spaces).
if self.isManager
| ^
controls/IDBrowser.py:102: [C0330(bad-continuation), ] Wrong continued indentation (remove 5 spaces).
else dv.DATAVIEW_CELL_INERT),
| ^
************* Module Beremiz_service
Beremiz_service.py:34: [W0611(unused-import), ] Unused import __builtin__
/**
 * Head of code common to all C targets
 **/

#include "beremiz.h"
#include <string.h>
/*
 * Prototypes of functions provided by generated C softPLC
 **/
void config_run__(unsigned long tick);
void config_init__(void);

/*
 * Prototypes of functions provided by generated target C code
 * */
long long AtomicCompareExchange64(long long*, long long, long long);
void __init_debug(void);
void __cleanup_debug(void);
/*void __retrieve_debug(void);*/
void __publish_debug(void);

/*
 *  Variables used by generated C softPLC and plugins
 **/
IEC_TIME __CURRENT_TIME;
IEC_BOOL __DEBUG = 0;
unsigned long __tick = 0;
char *PLC_ID = NULL;

/*
 *  Variable generated by C softPLC and plugins
 **/
extern unsigned long greatest_tick_count__;

/* Help to quit cleanly when init fail at a certain level */
static int init_level = 0;

/*
 * Prototypes of functions exported by plugins
 **/
%(calls_prototypes)s

/*
 * Retrieve input variables, run PLC and publish output variables
 **/
void __run(void)
{
    __tick++;
    if (greatest_tick_count__)
        __tick %%= greatest_tick_count__;

    %(retrieve_calls)s

    /*__retrieve_debug();*/

    config_run__(__tick);

    __publish_debug();

    %(publish_calls)s

}

/*
 * Initialize variables according to PLC's default values,
 * and then init plugins with that values
 **/
int __init(int argc,char **argv)
{
    int res = 0;
    init_level = 0;
    
    /* Effective tick time with 1ms default value */
    if(!common_ticktime__)
        common_ticktime__ = 1000000;

    config_init__();
    __init_debug();
    %(init_calls)s
    return res;
}
/*
 * Calls plugin cleanup proc.
 **/
void __cleanup(void)
{
    %(cleanup_calls)s
    __cleanup_debug();
}

void PLC_GetTime(IEC_TIME *CURRENT_TIME);
void PLC_SetTimer(unsigned long long next, unsigned long long period);