runtime/Stunnel.py
author Edouard Tisserant
Fri, 12 Jul 2019 11:51:47 +0200
changeset 2622 e10a1095f577
parent 2542 a3ec35ee94e7
child 3750 f62625418bff
permissions -rw-r--r--
Fixed repetitive freezing of IDE when connection drops.
when connection lost error was beeing displayed, the involved wxYield
was calling pending plc status periodic update, itself trying to use connector.
At that time connector is still not destroyed and connection
is attempted again when calling GetPLCStatus.
=> Hack : Ensure connector is destroyed before reporting error.
from __future__ import absolute_import
from __future__ import print_function
import os
from binascii import b2a_hqx
try:
    from runtime.spawn_subprocess import call
except ImportError:
    from subprocess import call

restart_stunnel_cmdline = ["/etc/init.d/S50stunnel", "restart"]

_PSKpath = None


def restartStunnel():
    """
    Restart stunnel service using SysV init stript
    to apply new generated credentials
    """
    try:
        call(restart_stunnel_cmdline)
    except OSError:
        print(_("Couldn't restart stunnel service"))


def PSKgen(ID, PSKpath):

    # b2a_hqx output len is 4/3 input len
    secret = os.urandom(192)  # int(256/1.3333)
    secretstring = b2a_hqx(secret)

    PSKstring = ID+":"+secretstring
    with open(PSKpath, 'w') as f:
        f.write(PSKstring)
    restartStunnel()


def ensurePSK(ID, PSKpath):
    global _PSKpath
    _PSKpath = PSKpath
    # check if already there
    if not os.path.exists(PSKpath):
        # create if needed
        PSKgen(ID, PSKpath)


def getPSKID(errorlog):
    if _PSKpath is not None:
        if not os.path.exists(_PSKpath):
            errorlog(
                'Error: Pre-Shared-Key Secret in %s is missing!\n' % _PSKpath)
            return None
        ID, _sep, PSK = open(_PSKpath).read().partition(':')
        PSK = PSK.rstrip('\n\r')
        return (ID, PSK)
    return None