Changed runtime's global PLCID to PLC_ID, working around redefinition in windoze' headers.
import os, re
from lxml import etree
from xmlclass import GenerateParserFromXSD
from CodeFileTreeNode import CodeFile
from PythonEditor import PythonEditor
class PythonFileCTNMixin(CodeFile):
CODEFILE_NAME = "PyFile"
SECTIONS_NAMES = [
"globals",
"init",
"cleanup",
"start",
"stop"]
EditorType = PythonEditor
def __init__(self):
CodeFile.__init__(self)
filepath = self.PythonFileName()
if os.path.isfile(filepath):
PythonParser = GenerateParserFromXSD(
os.path.join(os.path.dirname(__file__), "py_ext_xsd.xsd"))
xmlfile = open(filepath, 'r')
pythonfile_xml = xmlfile.read()
xmlfile.close()
pythonfile_xml = pythonfile_xml.replace(
'xmlns="http://www.w3.org/2001/XMLSchema"',
'xmlns:xhtml="http://www.w3.org/1999/xhtml"')
for cre, repl in [
(re.compile("(?<!<xhtml:p>)(?:<!\[CDATA\[)"), "<xhtml:p><![CDATA["),
(re.compile("(?:]]>)(?!</xhtml:p>)"), "]]></xhtml:p>")]:
pythonfile_xml = cre.sub(repl, pythonfile_xml)
try:
python_code, error = PythonParser.LoadXMLString(pythonfile_xml)
if error is None:
self.CodeFile.globals.setanyText(python_code.getanyText())
os.remove(filepath)
self.CreateCodeFileBuffer(False)
self.OnCTNSave()
except Exception, exc:
error = unicode(exc)
if error is not None:
self.GetCTRoot().logger.write_error(
_("Couldn't import old %s file.") % self.CTNName())
def CodeFileName(self):
return os.path.join(self.CTNPath(), "pyfile.xml")
def PythonFileName(self):
return os.path.join(self.CTNPath(), "py_ext.xml")
PreSectionsTexts = {}
PostSectionsTexts = {}
def GetSection(self,section):
return self.PreSectionsTexts.get(section,"") + "\n" + \
getattr(self.CodeFile, section).getanyText() + "\n" + \
self.PostSectionsTexts.get(section,"")
def CTNGenerate_C(self, buildpath, locations):
# location string for that CTN
location_str = "_".join(map(lambda x:str(x),
self.GetCurrentLocation()))
configname = self.GetCTRoot().GetProjectConfigNames()[0]
pyextname = self.CTNName()
varinfos = map(lambda variable : {
"name": variable.getname(),
"desc" : repr(variable.getdesc()),
"onchangecode" : '"'+variable.getonchange()+\
"('"+variable.getname()+"')\"" \
if variable.getonchange() else '""',
"onchange" : repr(variable.getonchange()) \
if variable.getonchange() else None,
"opts" : repr(variable.getopts()),
"configname" : configname.upper(),
"uppername" : variable.getname().upper(),
"IECtype" : variable.gettype(),
"pyextname" :pyextname},
self.CodeFile.variables.variable)
# python side PLC global variables access stub
globalstubs = "\n".join(["""\
_%(name)s_ctype, _%(name)s_unpack, _%(name)s_pack = \\
TypeTranslator["%(IECtype)s"]
_PySafeGetPLCGlob_%(name)s = PLCBinary.__SafeGetPLCGlob_%(name)s
_PySafeGetPLCGlob_%(name)s.restype = None
_PySafeGetPLCGlob_%(name)s.argtypes = [ctypes.POINTER(_%(name)s_ctype)]
_PySafeSetPLCGlob_%(name)s = PLCBinary.__SafeSetPLCGlob_%(name)s
_PySafeSetPLCGlob_%(name)s.restype = None
_PySafeSetPLCGlob_%(name)s.argtypes = [ctypes.POINTER(_%(name)s_ctype)]
_%(pyextname)sGlobalsDesc.append((
"%(name)s",
"%(IECtype)s",
%(desc)s,
%(onchange)s,
%(opts)s))
""" % varinfo
for varinfo in varinfos])
# Runtime calls (start, stop, init, and cleanup)
rtcalls = ""
for section in self.SECTIONS_NAMES:
if section != "globals":
rtcalls += "def _runtime_%s_%s():\n" % (location_str, section)
sectiontext = self.GetSection(section).strip()
if sectiontext:
rtcalls += ' ' + \
sectiontext.replace('\n', '\n ')+"\n\n"
else:
rtcalls += " pass\n\n"
globalsection = self.GetSection("globals")
PyFileContent = """\
#!/usr/bin/env python
# -*- coding: utf-8 -*-
## Code generated by Beremiz python mixin confnode
##
## Code for PLC global variable access
from targets.typemapping import TypeTranslator
import ctypes
_%(pyextname)sGlobalsDesc = []
__ext_name__ = "%(pyextname)s"
PLCGlobalsDesc.append(( "%(pyextname)s" , _%(pyextname)sGlobalsDesc ))
%(globalstubs)s
## User code in "global" scope
%(globalsection)s
## Beremiz python runtime calls
%(rtcalls)s
del __ext_name__
""" % locals()
# write generated content to python file
runtimefile_path = os.path.join(buildpath,
"runtime_%s.py"%location_str)
runtimefile = open(runtimefile_path, 'w')
runtimefile.write(PyFileContent.encode('utf-8'))
runtimefile.close()
# C code for safe global variables access
vardecfmt = """\
extern __IEC_%(IECtype)s_t %(configname)s__%(uppername)s;
IEC_%(IECtype)s __%(name)s_rbuffer = __INIT_%(IECtype)s;
IEC_%(IECtype)s __%(name)s_wbuffer;
long __%(name)s_rlock = 0;
long __%(name)s_wlock = 0;
int __%(name)s_wbuffer_written = 0;
void __SafeGetPLCGlob_%(name)s(IEC_%(IECtype)s *pvalue){
while(AtomicCompareExchange(&__%(name)s_rlock, 0, 1));
*pvalue = __%(name)s_rbuffer;
AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
}
void __SafeSetPLCGlob_%(name)s(IEC_%(IECtype)s *value){
while(AtomicCompareExchange(&__%(name)s_wlock, 0, 1));
__%(name)s_wbuffer = *value;
__%(name)s_wbuffer_written = 1;
AtomicCompareExchange((long*)&__%(name)s_wlock, 1, 0);
}
"""
vardeconchangefmt = """\
PYTHON_POLL* __%(name)s_notifier;
"""
varretfmt = """\
if(!AtomicCompareExchange(&__%(name)s_wlock, 0, 1)){
if(__%(name)s_wbuffer_written == 1){
%(configname)s__%(uppername)s.value = __%(name)s_wbuffer;
__%(name)s_wbuffer_written = 0;
}
AtomicCompareExchange((long*)&__%(name)s_wlock, 1, 0);
}
"""
varpubfmt = """\
if(!AtomicCompareExchange(&__%(name)s_rlock, 0, 1)){
__%(name)s_rbuffer = __GET_VAR(%(configname)s__%(uppername)s);
AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
}
"""
varpubonchangefmt = """\
if(!AtomicCompareExchange(&__%(name)s_rlock, 0, 1)){
IEC_%(IECtype)s tmp = __GET_VAR(%(configname)s__%(uppername)s);
if(__%(name)s_rbuffer != tmp){
__%(name)s_rbuffer = %(configname)s__%(uppername)s.value;
PYTHON_POLL_body__(__%(name)s_notifier);
}
AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
}
"""
varinitonchangefmt = """\
__%(name)s_notifier = __GET_GLOBAL_ON%(uppername)sCHANGE();
__SET_VAR(__%(name)s_notifier->,TRIG,,__BOOL_LITERAL(TRUE));
__SET_VAR(__%(name)s_notifier->,CODE,,__STRING_LITERAL(%(onchangelen)d,%(onchangecode)s));
"""
vardec = "\n".join([(vardecfmt + vardeconchangefmt
if varinfo["onchange"] else vardecfmt)% varinfo
for varinfo in varinfos])
varret = "\n".join([varretfmt % varinfo for varinfo in varinfos])
varpub = "\n".join([(varpubonchangefmt if varinfo["onchange"] else
varpubfmt) % varinfo
for varinfo in varinfos])
varinit = "\n".join([varinitonchangefmt % dict(
onchangelen = len(varinfo["onchangecode"]),**varinfo)
for varinfo in varinfos if varinfo["onchange"]])
# TODO : use config name obtained from model instead of default
# "config.h". User cannot change config name, but project imported
# or created in older beremiz vesion could use different name.
PyCFileContent = """\
/*
* Code generated by Beremiz py_ext confnode
* for safe global variables access
*/
#include "iec_types_all.h"
#include "POUS.h"
#include "config.h"
#include "beremiz.h"
/* User variables reference */
%(vardec)s
/* Beremiz confnode functions */
int __init_%(location_str)s(int argc,char **argv){
%(varinit)s
return 0;
}
void __cleanup_%(location_str)s(void){
}
void __retrieve_%(location_str)s(void){
%(varret)s
}
void __publish_%(location_str)s(void){
%(varpub)s
}
""" % locals()
Gen_PyCfile_path = os.path.join(buildpath, "PyCFile_%s.c"%location_str)
pycfile = open(Gen_PyCfile_path,'w')
pycfile.write(PyCFileContent)
pycfile.close()
matiec_flags = '"-I%s"'%os.path.abspath(
self.GetCTRoot().GetIECLibPath())
return ([(Gen_PyCfile_path, matiec_flags)],
"",
True,
("runtime_%s.py"%location_str, file(runtimefile_path,"rb")))