targets/plc_main_head.c
author Edouard Tisserant <edouard@beremiz.fr>
Thu, 05 Dec 2024 13:56:59 +0100
changeset 4060 d2f5eb3c7d6e
parent 3947 9b5cb90297e4
permissions -rw-r--r--
py_ext: fix CSV Writer

fix POU logic :
- SAVE is a BOOL
- invocation of py_eval on rising edge of SAVE
- remove save python argument

fix python:
- use no encoding for file open (python2)
- re-use detected dialect if any
- use no "rt+" and truncate since no need to re-sniff dialect for output file
- return "OK" instead of "#SUCCESS", preventing POU logic to ACK result
- support creating new line if writing just after last line
- support appending data on short rows

fix example:
- use a HMI:Button to trigger CSV write instead of HMI:Input +1
- reload CSVs on on each new CSV opened in file browser
- add display of CSV write output
/**
 * Head of code common to all C targets
 **/

#include "beremiz.h"
#include <string.h>
/*
 * Prototypes of functions provided by generated C softPLC
 **/
void config_run__(unsigned int tick);
void config_init__(void);

/*
 * Prototypes of functions provided by generated target C code
 * */
long long AtomicCompareExchange64(long long*, long long, long long);
void __init_debug(void);
void __cleanup_debug(void);
/*void __retrieve_debug(void);*/
void __publish_debug(void);

/*
 *  Variables used by generated C softPLC and plugins
 **/
IEC_TIME __CURRENT_TIME;
IEC_BOOL __DEBUG = 0;
unsigned int __tick = 0;
char *PLC_ID = NULL;

/*
 *  Variable generated by C softPLC and plugins
 **/
extern unsigned int greatest_tick_count__;

/* Help to quit cleanly when init fail at a certain level */
static int init_level = 0;

/*
 * Prototypes of functions exported by plugins
 **/
%(calls_prototypes)s

/*
 * Retrieve input variables, run PLC and publish output variables
 **/
void __run(void)
{
    __tick++;
    if (greatest_tick_count__)
        __tick %%= greatest_tick_count__;

    %(retrieve_calls)s

    /*__retrieve_debug();*/

    config_run__(__tick);

    __publish_debug();

    %(publish_calls)s

}

/*
 * Initialize variables according to PLC's default values,
 * and then init plugins with that values
 **/
int __init(int argc,char **argv)
{
    int res = 0;
    init_level = 0;
    
    /* Effective tick time with 1ms default value */
    if(!common_ticktime__)
        common_ticktime__ = 1000000;

    config_init__();
    __init_debug();
    %(init_calls)s
    return res;
}
/*
 * Calls plugin cleanup proc.
 **/
void __cleanup(void)
{
    %(cleanup_calls)s
    __cleanup_debug();
}

void PLC_GetTime(IEC_TIME *CURRENT_TIME);
void PLC_SetTimer(unsigned long long next, unsigned long long period);