tests/wiimote/py_ext_0@py_ext/pyfile.xml
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Thu, 16 Aug 2018 13:42:18 +0300
changeset 2289 cf0934b42d66
parent 1185 b36755d7c19e
permissions -rw-r--r--
Update README for WAMP example to use crossbar with python3

crossbar python2 support is broken in v18.7.2.
I've submitted with fixes for that.
https://github.com/crossbario/crossbar/pull/1376

But they don't test crossbar with python2 in CI, so it's going to be
broken again in the future.
And there is no much reason to use crossbar with python2.
<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<PyFile>
  <variables>
    <variable name="WiiNunchuckStickX" type="INT"/>
    <variable name="WiiNunchuckStickY" type="INT"/>
    <variable name="WiiNunchuckAccX" type="INT"/>
    <variable name="WiiNunchuckAccY" type="INT"/>
    <variable name="WiiNunchuckAccZ" type="INT"/>
    <variable name="WiiNunchuckButtons" type="WORD"/>
    <variable name="WiiButtons" type="WORD"/>
  </variables>
  <globals>
<![CDATA[
import cwiid,commands,sys,re,os,time

wiimote = None
WIIMOTE_ADDR_MODEL = re.compile("((?:[0-9A-F]{2})(?::[0-9A-F]{2}){5})\s*Nintendo")
nunchuckzero = None

def Wiimote_cback(messages, time):
    global nunchuckzero
    state = dict(messages)
    bts = state.get(cwiid.MESG_BTN, None)
    if bts is not None:
        PLCGlobals.WiiButtons = bts
    nunchuck = state.get(cwiid.MESG_NUNCHUK, None)
    if nunchuck is not None:
        PLCGlobals.WiiNunchuckButtons = nunchuck['buttons']
        X,Y = nunchuck['stick']
        PLCGlobals.WiiNunchuckAccX = nunchuck['acc'][cwiid.X]
        PLCGlobals.WiiNunchuckAccY = nunchuck['acc'][cwiid.Y]
        PLCGlobals.WiiNunchuckAccZ = nunchuck['acc'][cwiid.Z]
        if nunchuckzero is None:
            nunchuckzero = X,Y
        (PLCGlobals.WiiNunchuckStickX,
         PLCGlobals.WiiNunchuckStickY) = X-nunchuckzero[0],Y-nunchuckzero[1]

def Connect_Wiimote(connected_callback):
    global wiimote,nunchuckzero
    mac_addr = ''
    try:
        mac_addr = file("wiimac.txt","rt").read()
    except:
        PLCObject.LogMessage("Wiimote MAC unknown, scanning bluetooth")
        output = commands.getoutput("hcitool scan")
        result = WIIMOTE_ADDR_MODEL.search(output)
        if result is not None:
            mac_addr = result.group(1)
            PLCObject.LogMessage("Found Wiimote with MAC %s"%mac_addr)
            file("wiimac.txt","wt").write(mac_addr)
 
    # Connect to wiimote
    if not mac_addr:
        PLCObject.LogMessage("Connection to unknown Wiimote...")
        wiimote = cwiid.Wiimote()
    else:
        PLCObject.LogMessage("Connection to Wiimote %s..."%mac_addr)
        wiimote = cwiid.Wiimote(mac_addr)

    if wiimote is not None:
        nunchuckzero = None
        wiimote.rpt_mode = cwiid.RPT_BTN | cwiid.RPT_EXT
        # use the callback interface
        wiimote.mesg_callback = Wiimote_cback
        wiimote.enable(cwiid.FLAG_MESG_IFC)
        connected_callback(mac_addr)
        PLCObject.LogMessage("Wiimote %s Connected"%mac_addr)
    else:
        PLCObject.LogMessage("Wiimote %s not found"%mac_addr)
        os.remove("wiimac.txt")
        connected_callback(None)

def Disconnect_Wiimote():
  global wiimote
  if wiimote is not None:
    wiimote.disable(cwiid.FLAG_MESG_IFC)
    time.sleep(0.1)
    wiimote.close()
    wiimote = None
    PLCObject.LogMessage("Wiimote disconnected")

]]>
  </globals>
  <init>
<![CDATA[
]]>
  </init>
  <cleanup>
<![CDATA[
Disconnect_Wiimote()

]]>
  </cleanup>
  <start>
<![CDATA[
]]>
  </start>
  <stop>
<![CDATA[
]]>
  </stop>
</PyFile>