tests/canopen_slave/canopen@canfestival/slave@CanOpenSlave/slave.eds
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Wed, 01 Aug 2018 13:09:45 +0300
changeset 2258 c9915bc620cd
parent 411 8261c8f1e365
permissions -rw-r--r--
Fix wrong code generation if EN/ENO are used in FBD/LD/SFC

This problem appears for example here

--------
------- | MOVE |
| MOVE1 |------|EN ENO|
------- | |
| |
------- | | -----------
| 23 |------|IN OUT|---| LocalVar0 |
------- -------- -----------


--------
------- | MOVE |
| MOVE2 |------|EN ENO|
------- | |
| |
------- | | -----------
| 15 |------|IN OUT|---| LocalVar0 |
------- -------- -----------

Before wrong code was generated for this case:

MOVE6_OUT := MOVE(EN := move1, IN := 23, ENO => MOVE6_ENO);
LocalVar0 := MOVE6_OUT;
MOVE4_OUT := MOVE(EN := move2, IN := 15, ENO => MOVE4_ENO);
LocalVar0 := MOVE4_OUT;

With this patch now following code is generated:

MOVE6_OUT := MOVE(EN := move1, IN := 23, ENO => MOVE6_ENO);
IF MOVE6_ENO THEN
LocalVar0 := MOVE6_OUT;
END_IF;
MOVE4_OUT := MOVE(EN := move2, IN := 15, ENO => MOVE4_ENO);
IF MOVE4_ENO THEN
LocalVar0 := MOVE4_OUT;
END_IF;


See discussion here:
https://sourceforge.net/p/beremiz/mailman/message/36378805/
[FileInfo]
FileName=slave.eds
FileVersion=1
FileRevision=1
EDSVersion=4.0
Description=
CreationTime=09:10AM
CreationDate=10-27-2008
CreatedBy=CANFestival
ModificationTime=09:10AM
ModificationDate=10-27-2008
ModifiedBy=CANFestival

[DeviceInfo]
VendorName=CANFestival
VendorNumber=0x00000000
ProductName=SlaveNode
ProductNumber=0x00000000
RevisionNumber=0x00000000
BaudRate_10=1
BaudRate_20=1
BaudRate_50=1
BaudRate_125=1
BaudRate_250=1
BaudRate_500=1
BaudRate_800=1
BaudRate_1000=1
SimpleBootUpMaster=0
SimpleBootUpSlave=1
Granularity=8
DynamicChannelsSupported=0
CompactPDO=0
GroupMessaging=0
NrOfRXPDO=4
NrOfTXPDO=4
LSS_Supported=0

[DummyUsage]
Dummy0001=0
Dummy0002=1
Dummy0003=1
Dummy0004=1
Dummy0005=1
Dummy0006=1
Dummy0007=1

[Comments]
Lines=0

[MandatoryObjects]
SupportedObjects=3
1=0x1000
2=0x1001
3=0x1018

[1000]
ParameterName=Device Type
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0

[1001]
ParameterName=Error Register
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=0
PDOMapping=1

[1018]
ParameterName=Identity
ObjectType=0x8
SubNumber=5

[1018sub0]
ParameterName=Number of Entries
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=4
PDOMapping=0

[1018sub1]
ParameterName=Vendor ID
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0

[1018sub2]
ParameterName=Product Code
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0

[1018sub3]
ParameterName=Revision Number
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0

[1018sub4]
ParameterName=Serial Number
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0

[OptionalObjects]
SupportedObjects=1
1=0x1200

[1200]
ParameterName=Server SDO Parameter
ObjectType=0x8
SubNumber=3

[1200sub0]
ParameterName=Number of Entries
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=2
PDOMapping=0

[1200sub1]
ParameterName=COB ID Client to Server (Receive SDO)
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=$NODEID+0x600
PDOMapping=0

[1200sub2]
ParameterName=COB ID Server to Client (Transmit SDO)
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=$NODEID+0x580
PDOMapping=0

[ManufacturerObjects]
SupportedObjects=2
1=0x2000
2=0x2001

[2000]
ParameterName=OutVar
ObjectType=0x7
DataType=0x0003
AccessType=rw
DefaultValue=0
PDOMapping=1

[2001]
ParameterName=InVar
ObjectType=0x7
DataType=0x0003
AccessType=rw
DefaultValue=0
PDOMapping=1