runtime/webinterface.js
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Wed, 01 Aug 2018 13:09:45 +0300
changeset 2258 c9915bc620cd
parent 719 db54ccc96309
permissions -rw-r--r--
Fix wrong code generation if EN/ENO are used in FBD/LD/SFC

This problem appears for example here

--------
------- | MOVE |
| MOVE1 |------|EN ENO|
------- | |
| |
------- | | -----------
| 23 |------|IN OUT|---| LocalVar0 |
------- -------- -----------


--------
------- | MOVE |
| MOVE2 |------|EN ENO|
------- | |
| |
------- | | -----------
| 15 |------|IN OUT|---| LocalVar0 |
------- -------- -----------

Before wrong code was generated for this case:

MOVE6_OUT := MOVE(EN := move1, IN := 23, ENO => MOVE6_ENO);
LocalVar0 := MOVE6_OUT;
MOVE4_OUT := MOVE(EN := move2, IN := 15, ENO => MOVE4_ENO);
LocalVar0 := MOVE4_OUT;

With this patch now following code is generated:

MOVE6_OUT := MOVE(EN := move1, IN := 23, ENO => MOVE6_ENO);
IF MOVE6_ENO THEN
LocalVar0 := MOVE6_OUT;
END_IF;
MOVE4_OUT := MOVE(EN := move2, IN := 15, ENO => MOVE4_ENO);
IF MOVE4_ENO THEN
LocalVar0 := MOVE4_OUT;
END_IF;


See discussion here:
https://sourceforge.net/p/beremiz/mailman/message/36378805/
// import Nevow.Athena

function init() {
  Nevow.Athena.Widget.fromAthenaID(1).callRemote('HMIexec', 'HMIinitialisation');
}

WebInterface.PLC = Nevow.Athena.Widget.subclass('WebInterface.PLC');
WebInterface.PLC.method(
	 'updateHMI',
	 function (self, data) {
	   d = self.callRemote('getPLCElement');
	   d.addCallback(
			 function liveElementReceived(le) {
				d2 = self.addChildWidgetFromWidgetInfo(le);
				d2.addCallback(
						function childAdded(widget) {
						var node = self.nodeById('content');
						node.replaceChild(widget.node, node.getElementsByTagName('div')[0]);
						init();
						});
				});
	   });

Divmod.Base.addLoadEvent(init);