SVGHMI: Fixed problems happening when value is higher than maximum or lower than minimum in Input widget. "max" and "min" string was getting into keypad text field, was not diplayed systematically, and was staying forever sometime.
<?xml version="1.0" encoding="UTF-8"?>
<project xmlns="http://www.plcopen.org/xml/tc6.xsd"
xsi:schemaLocation="http://www.plcopen.org/xml/tc6.xsd"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:xhtml="http://www.w3.org/1999/xhtml">
<fileHeader companyName="Unknown"
productName="Unnamed"
productVersion="1"
creationDateTime="2013-01-29T14:01:00"/>
<contentHeader name="Unnamed"
modificationDateTime="2013-02-26T15:59:13">
<coordinateInfo>
<fbd>
<scaling x="0" y="0"/>
</fbd>
<ld>
<scaling x="0" y="0"/>
</ld>
<sfc>
<scaling x="0" y="0"/>
</sfc>
</coordinateInfo>
</contentHeader>
<types>
<dataTypes>
<dataType name="LOGLEVEL">
<baseType>
<enum>
<values>
<value name="CRITICAL"/>
<value name="WARNING"/>
<value name="INFO"/>
<value name="DEBUG"/>
</values>
</enum>
</baseType>
<initialValue>
<simpleValue value="INFO"/>
</initialValue>
</dataType>
</dataTypes>
<pous>
<pou name="LOGGER" pouType="functionBlock">
<interface>
<inputVars>
<variable name="TRIG">
<type>
<BOOL/>
</type>
</variable>
<variable name="MSG">
<type>
<string/>
</type>
</variable>
<variable name="LEVEL">
<type>
<derived name="LOGLEVEL"/>
</type>
<initialValue>
<simpleValue value="INFO"/>
</initialValue>
</variable>
</inputVars>
<localVars>
<variable name="TRIG0">
<type>
<BOOL/>
</type>
</variable>
</localVars>
</interface>
<body>
<ST>
<![CDATA[IF TRIG AND NOT TRIG0 THEN
{{
LogMessage(GetFbVar(LEVEL),(char*)GetFbVar(MSG, .body),GetFbVar(MSG, .len));
}}
END_IF;
TRIG0:=TRIG;
]]>
</ST>
</body>
</pou>
</pous>
</types>
<instances>
<configurations/>
</instances>
</project>