tests/canopen_master/plc.xml
author Schlumpf <schlumpf@kr-ll.de>
Fri, 15 Mar 2019 18:27:43 +0100
branchgenerate-button
changeset 2532 b9d6f5d7e0f1
parent 2346 ac16bad593cf
permissions -rw-r--r--
Create a "Generate Program As..." menu to make the "Generate Program" toolbutton even more useful.

The behaviour is the same as "Save" and "Save As...". Now "Generate Program" uses the last filename
if known and "Generate Progam As..." asks every time.
<?xml version='1.0' encoding='utf-8'?>
<project xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.plcopen.org/xml/tc6_0201" xmlns:xhtml="http://www.w3.org/1999/xhtml" xsi:schemaLocation="http://www.plcopen.org/xml/tc6_0201">
  <fileHeader companyName="beremiz" productName="beremiz" productVersion="1" creationDateTime="2008-06-24T18:44:00"/>
  <contentHeader name="canopen_master" modificationDateTime="2018-09-26T13:31:52" language="en-US">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes/>
    <pous>
      <pou name="test_main" pouType="program">
        <interface>
          <localVars>
            <variable name="PLC_OUT" address="%QW0.0.2.8193.0">
              <type>
                <INT/>
              </type>
            </variable>
            <variable name="PLC_IN" address="%IW0.0.2.8192.0">
              <type>
                <INT/>
              </type>
            </variable>
          </localVars>
        </interface>
        <body>
          <FBD>
            <outVariable localId="1" height="29" width="80" executionOrderId="0" negated="false">
              <position x="362" y="139"/>
              <connectionPointIn>
                <relPosition x="0" y="14"/>
                <connection refLocalId="4" formalParameter="OUT">
                  <position x="362" y="153"/>
                  <position x="299" y="153"/>
                </connection>
              </connectionPointIn>
              <expression>PLC_OUT</expression>
            </outVariable>
            <inVariable localId="2" height="29" width="20">
              <position x="100" y="115"/>
              <connectionPointOut>
                <relPosition x="20" y="14"/>
              </connectionPointOut>
              <expression>1</expression>
            </inVariable>
            <block localId="4" width="75" height="60" typeName="ADD">
              <position x="224" y="123"/>
              <inputVariables>
                <variable formalParameter="IN1">
                  <connectionPointIn>
                    <relPosition x="0" y="30"/>
                    <connection refLocalId="2">
                      <position x="224" y="153"/>
                      <position x="183" y="153"/>
                      <position x="183" y="129"/>
                      <position x="120" y="129"/>
                    </connection>
                  </connectionPointIn>
                </variable>
                <variable formalParameter="IN2">
                  <connectionPointIn>
                    <relPosition x="0" y="50"/>
                    <connection refLocalId="5">
                      <position x="224" y="173"/>
                      <position x="199" y="173"/>
                      <position x="199" y="201"/>
                      <position x="174" y="201"/>
                    </connection>
                  </connectionPointIn>
                </variable>
              </inputVariables>
              <inOutVariables/>
              <outputVariables>
                <variable formalParameter="OUT">
                  <connectionPointOut>
                    <relPosition x="75" y="30"/>
                  </connectionPointOut>
                </variable>
              </outputVariables>
            </block>
            <inVariable localId="5" height="29" width="70">
              <position x="104" y="187"/>
              <connectionPointOut>
                <relPosition x="70" y="14"/>
              </connectionPointOut>
              <expression>PLC_IN</expression>
            </inVariable>
          </FBD>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations>
      <configuration name="conf">
        <resource name="res">
          <task name="tache" interval="t#50ms" priority="0">
            <pouInstance name="toto" typeName="test_main"/>
          </task>
        </resource>
      </configuration>
    </configurations>
  </instances>
</project>