svghmi/widget_tooglebutton.ysl2
author Edouard Tisserant
Wed, 01 Mar 2023 10:54:54 +0100
changeset 3740 ac0e6de439b5
parent 3599 0d7c41546854
permissions -rw-r--r--
Linux runtime: overrun detection for real-time timers and for plc execution.

If real-time timer wakes-up PLC thread too late (10% over period), then
warning is logged.

If PLC code (IO retreive, execution, IO publish) takes longer than requested
PLC execution cycle, then warning is logged, and CPU hoogging is mitigated
by delaying next PLC execution a few cylces more until having at least
1ms minimal idle time.
// widget_tooglebutton.ysl2


widget_desc("ToggleButton") {
    longdesc
    ||
    Button widget takes one boolean variable path, and reflect current true
    or false value by showing "active" or "inactive" labeled element
    respectively. Clicking or touching button toggles variable.
    ||

    shortdesc > Toggle button reflecting given boolean variable

    path name="value" accepts="HMI_BOOL" > Boolean variable
    
}

widget_class("ToggleButton") {
    ||
        frequency = 5;
        active_style = undefined;
        inactive_style = undefined;

        dispatch(value) {
            this.activity_state = Boolean(value);
            //redraw toggle button
            this.request_animate();
        }

        on_click(evt) {
            //toggle state and apply
            this.activity_state = this.activity_state ? false : true;
            this.apply_hmi_value(0, this.activity_state);

            //redraw toggle button
            this.request_animate();
        }

        init() {
            this.element.onclick = (evt) => this.on_click(evt);
            this.activity_state = undefined;
        }
    ||
}

widget_defs("ToggleButton") {
    activable();
}