targets/plc_main_head.c
author usveticic
Thu, 01 Oct 2020 14:23:27 +0200
branchsvghmi
changeset 3062 9ec338a99a18
parent 2503 6ffeffb6d635
permissions -rw-r--r--
Button fix if no active or inactive state,
Widget animate changed to use anitmateTransform and added option to change rotation
Widget circular slider fixed so it is working on got and reprogramed so it similar to normal slider
Widget slider added support for changing size still need some changes to work properly
Added slider to svghmi test project
Changed svg in svhgmi_v2 project
/**
 * Head of code common to all C targets
 **/

#include "beremiz.h"
#include <string.h>
/*
 * Prototypes of functions provided by generated C softPLC
 **/
void config_run__(unsigned long tick);
void config_init__(void);

/*
 * Prototypes of functions provided by generated target C code
 * */
long long AtomicCompareExchange64(long long*, long long, long long);
void __init_debug(void);
void __cleanup_debug(void);
/*void __retrieve_debug(void);*/
void __publish_debug(void);

/*
 *  Variables used by generated C softPLC and plugins
 **/
IEC_TIME __CURRENT_TIME;
IEC_BOOL __DEBUG = 0;
unsigned long __tick = 0;
char *PLC_ID = NULL;

/*
 *  Variable generated by C softPLC and plugins
 **/
extern unsigned long greatest_tick_count__;

/* Help to quit cleanly when init fail at a certain level */
static int init_level = 0;

/*
 * Prototypes of functions exported by plugins
 **/
%(calls_prototypes)s

/*
 * Retrieve input variables, run PLC and publish output variables
 **/
void __run(void)
{
    __tick++;
    if (greatest_tick_count__)
        __tick %%= greatest_tick_count__;

    %(retrieve_calls)s

    /*__retrieve_debug();*/

    config_run__(__tick);

    __publish_debug();

    %(publish_calls)s

}

/*
 * Initialize variables according to PLC's default values,
 * and then init plugins with that values
 **/
int __init(int argc,char **argv)
{
    int res = 0;
    init_level = 0;
    
    /* Effective tick time with 1ms default value */
    if(!common_ticktime__)
        common_ticktime__ = 1000000;

    config_init__();
    __init_debug();
    %(init_calls)s
    return res;
}
/*
 * Calls plugin cleanup proc.
 **/
void __cleanup(void)
{
    %(cleanup_calls)s
    __cleanup_debug();
}

void PLC_GetTime(IEC_TIME *CURRENT_TIME);
void PLC_SetTimer(unsigned long long next, unsigned long long period);