NativeLib.xml
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Fri, 12 Oct 2018 13:24:47 +0300
changeset 2457 9deec258ab1a
parent 1050 56bef276055e
permissions -rw-r--r--
python3 support: pylint, W1633 # (round-builtin) round built-in referenced

because round behavior is changed to default behavior in Python3
(Banker round). It can cause slight differences in some cases.
Mostly graphical editors are affected, there could be single pixel differences.
Now I couldn't locate any visual differences in test programs.
<?xml version="1.0" encoding="UTF-8"?>
<project xmlns="http://www.plcopen.org/xml/tc6.xsd"
         xsi:schemaLocation="http://www.plcopen.org/xml/tc6.xsd"
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xmlns:xhtml="http://www.w3.org/1999/xhtml">
  <fileHeader companyName="Unknown"
              productName="Unnamed"
              productVersion="1"
              creationDateTime="2013-01-29T14:01:00"/>
  <contentHeader name="Unnamed"
                 modificationDateTime="2013-02-26T15:59:13">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes>
      <dataType name="LOGLEVEL">
        <baseType>
          <enum>
            <values>
              <value name="CRITICAL"/>
              <value name="WARNING"/>
              <value name="INFO"/>
              <value name="DEBUG"/>
            </values>
          </enum>
        </baseType>
        <initialValue>
          <simpleValue value="INFO"/>
        </initialValue>
      </dataType>
    </dataTypes>
    <pous>
      <pou name="LOGGER" pouType="functionBlock">
        <interface>
          <inputVars>
            <variable name="TRIG">
              <type>
                <BOOL/>
              </type>
            </variable>
            <variable name="MSG">
              <type>
                <string/>
              </type>
            </variable>
            <variable name="LEVEL">
              <type>
                <derived name="LOGLEVEL"/>
              </type>
              <initialValue>
                <simpleValue value="INFO"/>
              </initialValue>
            </variable>
          </inputVars>
          <localVars>
            <variable name="TRIG0">
              <type>
                <BOOL/>
              </type>
            </variable>
          </localVars>
        </interface>
        <body>
          <ST>
<![CDATA[IF TRIG AND NOT TRIG0 THEN
{{
 LogMessage(GetFbVar(LEVEL),(char*)GetFbVar(MSG, .body),GetFbVar(MSG, .len));
}}
END_IF;
TRIG0:=TRIG;
]]>
          </ST>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations/>
  </instances>
</project>