doc/overview.rst
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Thu, 07 Jun 2018 13:45:35 +0300
changeset 2173 976841968d74
parent 810 707e2be17a43
child 3925 1d383b4c0a23
permissions -rw-r--r--
Add retain basic implementation on GNU/Linux

Retain is saved in file and backup of this file is done every time.
File isn't saved on every PLC cycle to avoid high I/O load.
By default, retain is saved every second and on PLC stop/shutdown.
It's possible to override retain flush period by using CFLAGS option
in project's settings. For example, for 0.5 seconds period
use "-DFILE_RETAIN_SAVE_PERIOD_S=0.5".
Project overview
================

In order to target the widest possible range of programmable devices and keep efficient, Beremiz use C code as an intermediate language. 

To be executed, C needs to be compiled. `GCC <http://gcc.gnu.org>`_ serve that purpose perfectly.

PLC program is expressed in languages defined in IEC-61131, including graphical languages. Thanks to PLCopen TC2, those graphical languages have a standardised representation, in XML.

To be continued.