Xenomai runtime: report and mitigate when PLC cycle overruns.
Side effect :
_Log* macro was changed in plc_Xenomai_main.c,
and fixed in plc_Linux_main.c
/*
* Generated by erpcgen 1.11.0 on Wed Mar 27 13:43:44 2024.
*
* AUTOGENERATED - DO NOT EDIT
*/
#if !defined(_erpc_PLCObject_interface_hpp_)
#define _erpc_PLCObject_interface_hpp_
#include "erpc_PLCObject_common.hpp"
namespace erpcShim
{
// Abstract base class for BeremizPLCObjectService
class BeremizPLCObjectService_interface
{
public:
static const uint8_t m_serviceId = 1;
static const uint8_t m_AppendChunkToBlobId = 1;
static const uint8_t m_GetLogMessageId = 2;
static const uint8_t m_GetPLCIDId = 3;
static const uint8_t m_GetPLCstatusId = 4;
static const uint8_t m_GetTraceVariablesId = 5;
static const uint8_t m_MatchMD5Id = 6;
static const uint8_t m_NewPLCId = 7;
static const uint8_t m_PurgeBlobsId = 8;
static const uint8_t m_RepairPLCId = 9;
static const uint8_t m_ResetLogCountId = 10;
static const uint8_t m_SeedBlobId = 11;
static const uint8_t m_SetTraceVariablesListId = 12;
static const uint8_t m_StartPLCId = 13;
static const uint8_t m_StopPLCId = 14;
virtual ~BeremizPLCObjectService_interface(void);
virtual uint32_t AppendChunkToBlob(const binary_t * data, const binary_t * blobID, binary_t * newBlobID) = 0;
virtual uint32_t GetLogMessage(uint8_t level, uint32_t msgID, log_message * message) = 0;
virtual uint32_t GetPLCID(PSKID * plcID) = 0;
virtual uint32_t GetPLCstatus(PLCstatus * status) = 0;
virtual uint32_t GetTraceVariables(uint32_t debugToken, TraceVariables * traces) = 0;
virtual uint32_t MatchMD5(const char * MD5, bool * match) = 0;
virtual uint32_t NewPLC(const char * md5sum, const binary_t * plcObjectBlobID, const list_extra_file_1_t * extrafiles, bool * success) = 0;
virtual uint32_t PurgeBlobs(void) = 0;
virtual uint32_t RepairPLC(void) = 0;
virtual uint32_t ResetLogCount(void) = 0;
virtual uint32_t SeedBlob(const binary_t * seed, binary_t * blobID) = 0;
virtual uint32_t SetTraceVariablesList(const list_trace_order_1_t * orders, uint32_t * debugtoken) = 0;
virtual uint32_t StartPLC(void) = 0;
virtual uint32_t StopPLC(bool * success) = 0;
private:
};
} // erpcShim