fix many compilation warnings about static variables used by non-static functions
[CC] plc_main.c -> plc_main.o
/tmp/be/build/plc_main.c:396:40: warning: ?LogBuff? is static but used in inline function ?copy_from_log? which is not static
memcpy((char*)buf + remaining, LogBuff[level], size - remaining);
^
/tmp/be/build/plc_main.c:395:22: warning: ?LogBuff? is static but used in inline function ?copy_from_log? which is not static
memcpy(buf, &LogBuff[level][buffpos], remaining);
^
...
^
/tmp/be/build/plc_debugger.c:825:20: warning: ?retain_offset? is static but used in inline function ?BufferIterator? which is not static
Retain(retain_offset, size, real_value_p);
^
/tmp/be/build/plc_debugger.c:823:47: warning: ?retain_offset? is static but used in inline function ?BufferIterator? which is not static
unsigned int next_retain_offset = retain_offset + size;
^
^
/**
* Head of code common to all C targets
**/
#include "beremiz.h"
#include <string.h>
/*
* Prototypes of functions provided by generated C softPLC
**/
void config_run__(unsigned long tick);
void config_init__(void);
/*
* Prototypes of functions provided by generated target C code
* */
long long AtomicCompareExchange64(long long*, long long, long long);
void __init_debug(void);
void __cleanup_debug(void);
/*void __retrieve_debug(void);*/
void __publish_debug(void);
/*
* Variables used by generated C softPLC and plugins
**/
IEC_TIME __CURRENT_TIME;
IEC_BOOL __DEBUG = 0;
unsigned long __tick = 0;
char *PLC_ID = NULL;
/*
* Variable generated by C softPLC and plugins
**/
extern unsigned long greatest_tick_count__;
/* Help to quit cleanly when init fail at a certain level */
static int init_level = 0;
/*
* Prototypes of functions exported by plugins
**/
%(calls_prototypes)s
/*
* Retrieve input variables, run PLC and publish output variables
**/
void __run(void)
{
__tick++;
if (greatest_tick_count__)
__tick %%= greatest_tick_count__;
%(retrieve_calls)s
/*__retrieve_debug();*/
config_run__(__tick);
__publish_debug();
%(publish_calls)s
}
/*
* Initialize variables according to PLC's default values,
* and then init plugins with that values
**/
int __init(int argc,char **argv)
{
int res = 0;
init_level = 0;
/* Effective tick time with 1ms default value */
if(!common_ticktime__)
common_ticktime__ = 1000000;
config_init__();
__init_debug();
%(init_calls)s
return res;
}
/*
* Calls plugin cleanup proc.
**/
void __cleanup(void)
{
%(cleanup_calls)s
__cleanup_debug();
}
void PLC_GetTime(IEC_TIME *CURRENT_TIME);
void PLC_SetTimer(unsigned long long next, unsigned long long period);