Added 'NamedConstant' drag'n'drop in programs. It does create a simple variable with initial value and is usefull for drag'n'drop constants from extensions while keeping a name associated with constant
import os, re
from lxml import etree
from xmlclass import GenerateParserFromXSD
from CodeFileTreeNode import CodeFile
from PythonEditor import PythonEditor
class PythonFileCTNMixin(CodeFile):
CODEFILE_NAME = "PyFile"
SECTIONS_NAMES = [
"globals",
"init",
"cleanup",
"start",
"stop"]
EditorType = PythonEditor
def __init__(self):
CodeFile.__init__(self)
filepath = self.PythonFileName()
if os.path.isfile(filepath):
PythonParser = GenerateParserFromXSD(
os.path.join(os.path.dirname(__file__), "py_ext_xsd.xsd"))
xmlfile = open(filepath, 'r')
pythonfile_xml = xmlfile.read()
xmlfile.close()
pythonfile_xml = pythonfile_xml.replace(
'xmlns="http://www.w3.org/2001/XMLSchema"',
'xmlns:xhtml="http://www.w3.org/1999/xhtml"')
for cre, repl in [
(re.compile("(?<!<xhtml:p>)(?:<!\[CDATA\[)"), "<xhtml:p><![CDATA["),
(re.compile("(?:]]>)(?!</xhtml:p>)"), "]]></xhtml:p>")]:
pythonfile_xml = cre.sub(repl, pythonfile_xml)
try:
python_code, error = PythonParser.LoadXMLString(pythonfile_xml)
if error is None:
self.CodeFile.globals.setanyText(python_code.getanyText())
os.remove(filepath)
self.CreateCodeFileBuffer(False)
self.OnCTNSave()
except Exception, exc:
error = unicode(exc)
if error is not None:
self.GetCTRoot().logger.write_error(
_("Couldn't import old %s file.") % CTNName)
def CodeFileName(self):
return os.path.join(self.CTNPath(), "pyfile.xml")
def PythonFileName(self):
return os.path.join(self.CTNPath(), "py_ext.xml")
PreSectionsTexts = {}
PostSectionsTexts = {}
def GetSection(self,section):
return self.PreSectionsTexts.get(section,"") + "\n" + \
getattr(self.CodeFile, section).getanyText() + "\n" + \
self.PostSectionsTexts.get(section,"")
def CTNGenerate_C(self, buildpath, locations):
# location string for that CTN
location_str = "_".join(map(lambda x:str(x),
self.GetCurrentLocation()))
configname = self.GetCTRoot().GetProjectConfigNames()[0]
# python side PLC global variables access stub
globalstubs = "\n".join(["""\
_%(name)s_ctype, _%(name)s_unpack, _%(name)s_pack = \\
TypeTranslator["%(IECtype)s"]
_PySafeGetPLCGlob_%(name)s = PLCBinary.__SafeGetPLCGlob_%(name)s
_PySafeGetPLCGlob_%(name)s.restype = None
_PySafeGetPLCGlob_%(name)s.argtypes = [ctypes.POINTER(_%(name)s_ctype)]
_PySafeSetPLCGlob_%(name)s = PLCBinary.__SafeSetPLCGlob_%(name)s
_PySafeSetPLCGlob_%(name)s.restype = None
_PySafeSetPLCGlob_%(name)s.argtypes = [ctypes.POINTER(_%(name)s_ctype)]
""" % { "name": variable.getname(),
"configname": configname.upper(),
"uppername": variable.getname().upper(),
"IECtype": variable.gettype()}
for variable in self.CodeFile.variables.variable])
# Runtime calls (start, stop, init, and cleanup)
rtcalls = ""
for section in self.SECTIONS_NAMES:
if section != "globals":
rtcalls += "def _runtime_%s_%s():\n" % (location_str, section)
sectiontext = self.GetSection(section).strip()
if sectiontext:
rtcalls += ' ' + \
sectiontext.replace('\n', '\n ')+"\n\n"
else:
rtcalls += " pass\n\n"
globalsection = self.GetSection("globals")
PyFileContent = """\
#!/usr/bin/env python
# -*- coding: utf-8 -*-
## Code generated by Beremiz python mixin confnode
##
## Code for PLC global variable access
from targets.typemapping import TypeTranslator
import ctypes
%(globalstubs)s
## User code in "global" scope
%(globalsection)s
## Beremiz python runtime calls
%(rtcalls)s
""" % locals()
# write generated content to python file
runtimefile_path = os.path.join(buildpath,
"runtime_%s.py"%location_str)
runtimefile = open(runtimefile_path, 'w')
runtimefile.write(PyFileContent.encode('utf-8'))
runtimefile.close()
# C code for safe global variables access
vardecfmt = """\
extern __IEC_%(IECtype)s_t %(configname)s__%(uppername)s;
IEC_%(IECtype)s __%(name)s_rbuffer = __INIT_%(IECtype)s;
IEC_%(IECtype)s __%(name)s_wbuffer;
long __%(name)s_rlock = 0;
long __%(name)s_wlock = 0;
int __%(name)s_wbuffer_written = 0;
void __SafeGetPLCGlob_%(name)s(IEC_%(IECtype)s *pvalue){
while(AtomicCompareExchange(&__%(name)s_rlock, 0, 1));
*pvalue = __%(name)s_rbuffer;
AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
}
void __SafeSetPLCGlob_%(name)s(IEC_%(IECtype)s *value){
while(AtomicCompareExchange(&__%(name)s_wlock, 0, 1));
__%(name)s_wbuffer = *value;
__%(name)s_wbuffer_written = 1;
AtomicCompareExchange((long*)&__%(name)s_wlock, 1, 0);
}
"""
varretfmt = """\
if(!AtomicCompareExchange(&__%(name)s_wlock, 0, 1)){
if(__%(name)s_wbuffer_written == 1){
%(configname)s__%(uppername)s.value = __%(name)s_wbuffer;
__%(name)s_wbuffer_written = 0;
}
AtomicCompareExchange((long*)&__%(name)s_wlock, 1, 0);
}
"""
varpubfmt = """\
if(!AtomicCompareExchange(&__%(name)s_rlock, 0, 1)){
__%(name)s_rbuffer = %(configname)s__%(uppername)s.value;
AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
}
"""
var_str = map("\n".join, zip(*[
map(lambda f : f % varinfo,
(vardecfmt, varretfmt, varpubfmt))
for varinfo in map(lambda variable : {
"name": variable.getname(),
"configname": configname.upper(),
"uppername": variable.getname().upper(),
"IECtype": variable.gettype()},
self.CodeFile.variables.variable)]))
if len(var_str) > 0:
vardec, varret, varpub = var_str
else:
vardec = varret = varpub = ""
PyCFileContent = """\
/*
* Code generated by Beremiz py_ext confnode
* for safe global variables access
*/
#include "iec_types_all.h"
#include "beremiz.h"
/* User variables reference */
%(vardec)s
/* Beremiz confnode functions */
int __init_%(location_str)s(int argc,char **argv){
return 0;
}
void __cleanup_%(location_str)s(void){
}
void __retrieve_%(location_str)s(void){
%(varret)s
}
void __publish_%(location_str)s(void){
%(varpub)s
}
""" % locals()
Gen_PyCfile_path = os.path.join(buildpath, "PyCFile_%s.c"%location_str)
pycfile = open(Gen_PyCfile_path,'w')
pycfile.write(PyCFileContent)
pycfile.close()
matiec_flags = '"-I%s"'%os.path.abspath(
self.GetCTRoot().GetIECLibPath())
return ([(Gen_PyCfile_path, matiec_flags)],
"",
True,