tests/canopen_master/plc.xml
author Edouard Tisserant
Fri, 15 Jun 2018 09:48:05 +0200
changeset 2188 7f59aa398669
parent 436 c926a8037adc
child 2346 ac16bad593cf
permissions -rw-r--r--
WxGlade HMI extension now does only instanciate wx object who's name match extension's name. If no object match the name and no code is provided in 'start' user python code section, then a warning is issued
<?xml version="1.0" encoding="UTF-8"?>
<project xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xmlns="http://www.plcopen.org/xml/tc6.xsd"
         xmlns:xhtml="http://www.w3.org/1999/xhtml"
         xsi:schemaLocation="http://www.plcopen.org/xml/tc6.xsd">
  <fileHeader companyName="beremiz"
              productName="beremiz"
              productVersion="1"
              creationDateTime="2008-06-24T18:44:00"/>
  <contentHeader name="canopen_master"
                 modificationDateTime="2009-10-07T18:45:11"
                 language="en-US">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes/>
    <pous>
      <pou name="test_main" pouType="program">
        <interface>
          <localVars>
            <variable name="PLC_OUT" address="%QW0.0.2.8193.0">
              <type>
                <INT/>
              </type>
            </variable>
            <variable name="PLC_IN" address="%IW0.0.2.8192.0">
              <type>
                <INT/>
              </type>
            </variable>
          </localVars>
        </interface>
        <body>
          <FBD>
            <outVariable localId="1" height="29" width="80">
              <position x="362" y="140"/>
              <connectionPointIn>
                <relPosition x="0" y="14"/>
                <connection refLocalId="4" formalParameter="OUT">
                  <position x="362" y="154"/>
                  <position x="330" y="154"/>
                  <position x="330" y="153"/>
                  <position x="299" y="153"/>
                </connection>
              </connectionPointIn>
              <expression>PLC_OUT</expression>
            </outVariable>
            <inVariable localId="2" height="29" width="20">
              <position x="100" y="115"/>
              <connectionPointOut>
                <relPosition x="20" y="14"/>
              </connectionPointOut>
              <expression>1</expression>
            </inVariable>
            <block localId="4" width="75" height="60" typeName="ADD">
              <position x="224" y="123"/>
              <inputVariables>
                <variable formalParameter="IN1">
                  <connectionPointIn>
                    <relPosition x="0" y="30"/>
                    <connection refLocalId="2">
                      <position x="224" y="153"/>
                      <position x="183" y="153"/>
                      <position x="183" y="129"/>
                      <position x="120" y="129"/>
                    </connection>
                  </connectionPointIn>
                </variable>
                <variable formalParameter="IN2">
                  <connectionPointIn>
                    <relPosition x="0" y="50"/>
                    <connection refLocalId="5">
                      <position x="224" y="173"/>
                      <position x="199" y="173"/>
                      <position x="199" y="201"/>
                      <position x="174" y="201"/>
                    </connection>
                  </connectionPointIn>
                </variable>
              </inputVariables>
              <inOutVariables/>
              <outputVariables>
                <variable formalParameter="OUT">
                  <connectionPointOut>
                    <relPosition x="75" y="30"/>
                  </connectionPointOut>
                </variable>
              </outputVariables>
            </block>
            <inVariable localId="5" height="29" width="70">
              <position x="104" y="187"/>
              <connectionPointOut>
                <relPosition x="70" y="14"/>
              </connectionPointOut>
              <expression>PLC_IN</expression>
            </inVariable>
          </FBD>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations>
      <configuration name="conf">
        <resource name="res">
          <task name="tache" interval="t#50ms" priority="0">
            <pouInstance name="toto" typeName="test_main"/>
          </task>
        </resource>
      </configuration>
    </configurations>
  </instances>
</project>