Modbus and Bacnet websettings : Rename variables and functions to avoid name collisions.
Websettings for modbus and bacnet are now passed to runtime as python files loaded (execfile) at init of PLCObject with the same globals.
Because if this, same names used in previously different modules now colide.
<?xml version='1.0' encoding='utf-8'?>
<PyFile xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<variables/>
<globals>
<xhtml:p><![CDATA[import threading, time
MyT = None
Stop = False
def StartLog():
global MyT
MyT=threading.Thread(target = DoLog)
MyT.start()
def DoLog():
global Stop
while not Stop:
PLCObject.LogMessage("Python side Logging (PLC is %s)"%PLCObject.PLCStatus)
time.sleep(0.3)
def StopLog():
global MyT,Stop
Stop=True
_runtime_init.append(StartLog)
_runtime_cleanup.append(StopLog)
]]></xhtml:p>
</globals>
<init>
<xhtml:p><![CDATA[]]></xhtml:p>
</init>
<cleanup>
<xhtml:p><![CDATA[]]></xhtml:p>
</cleanup>
<start>
<xhtml:p><![CDATA[]]></xhtml:p>
</start>
<stop>
<xhtml:p><![CDATA[]]></xhtml:p>
</stop>
</PyFile>