Fix non-marking as manually forced floating point variable if the value isn't integer
For example, if user in debug variable panel set any floating point
variable to 34.3, then it's not shown as forced (blue color) and user
can't release this enforcement.
If user changes the value to 34.0, then enforcement shows
correctly. This is done because binary representation of floating point
numbers in IDE and runtime can be slightly different (double vs float)
and as a result values aren't equal.
[FileInfo]
FileName=slave.eds
FileVersion=1
FileRevision=1
EDSVersion=4.0
Description=
CreationTime=09:10AM
CreationDate=10-27-2008
CreatedBy=CANFestival
ModificationTime=09:10AM
ModificationDate=10-27-2008
ModifiedBy=CANFestival
[DeviceInfo]
VendorName=CANFestival
VendorNumber=0x00000000
ProductName=SlaveNode
ProductNumber=0x00000000
RevisionNumber=0x00000000
BaudRate_10=1
BaudRate_20=1
BaudRate_50=1
BaudRate_125=1
BaudRate_250=1
BaudRate_500=1
BaudRate_800=1
BaudRate_1000=1
SimpleBootUpMaster=0
SimpleBootUpSlave=1
Granularity=8
DynamicChannelsSupported=0
CompactPDO=0
GroupMessaging=0
NrOfRXPDO=4
NrOfTXPDO=4
LSS_Supported=0
[DummyUsage]
Dummy0001=0
Dummy0002=1
Dummy0003=1
Dummy0004=1
Dummy0005=1
Dummy0006=1
Dummy0007=1
[Comments]
Lines=0
[MandatoryObjects]
SupportedObjects=3
1=0x1000
2=0x1001
3=0x1018
[1000]
ParameterName=Device Type
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1001]
ParameterName=Error Register
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=0
PDOMapping=1
[1018]
ParameterName=Identity
ObjectType=0x8
SubNumber=5
[1018sub0]
ParameterName=Number of Entries
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=4
PDOMapping=0
[1018sub1]
ParameterName=Vendor ID
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1018sub2]
ParameterName=Product Code
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1018sub3]
ParameterName=Revision Number
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1018sub4]
ParameterName=Serial Number
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[OptionalObjects]
SupportedObjects=1
1=0x1200
[1200]
ParameterName=Server SDO Parameter
ObjectType=0x8
SubNumber=3
[1200sub0]
ParameterName=Number of Entries
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=2
PDOMapping=0
[1200sub1]
ParameterName=COB ID Client to Server (Receive SDO)
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=$NODEID+0x600
PDOMapping=0
[1200sub2]
ParameterName=COB ID Server to Client (Transmit SDO)
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=$NODEID+0x580
PDOMapping=0
[ManufacturerObjects]
SupportedObjects=2
1=0x2000
2=0x2001
[2000]
ParameterName=OutVar
ObjectType=0x7
DataType=0x0003
AccessType=rw
DefaultValue=0
PDOMapping=1
[2001]
ParameterName=InVar
ObjectType=0x7
DataType=0x0003
AccessType=rw
DefaultValue=0
PDOMapping=1