Avoid usage of localized strings before initialization during import in many modules

This happens if import is done before i18n setup
(InstallLocalRessources()).
This affects PLCOpenEditor mostly. Beremiz IDE is free from this issue, but moving
initialization from import should make modules more robust.
Otherwise execution result depends on where and when import was done
and this is not a good thing.

Some modules (ConfigTreeNode, features, CodeFileEditor related
classes) still have this, but they are used only in Beremiz.
Most problems result in non-working internatialization.
In some cases (VariablePanel) there is backtrace, because localized
key is not found in non-localized dictionary.
/**
 * Head of code common to all C targets
 **/

#include "beremiz.h"
#include <string.h>
/*
 * Prototypes of functions provided by generated C softPLC
 **/
void config_run__(unsigned long tick);
void config_init__(void);

/*
 * Prototypes of functions provided by generated target C code
 * */
long long AtomicCompareExchange64(long long*, long long, long long);
void __init_debug(void);
void __cleanup_debug(void);
/*void __retrieve_debug(void);*/
void __publish_debug(void);

/*
 *  Variables used by generated C softPLC and plugins
 **/
IEC_TIME __CURRENT_TIME;
IEC_BOOL __DEBUG = 0;
unsigned long __tick = 0;
char *PLC_ID = NULL;

/*
 *  Variable generated by C softPLC and plugins
 **/
extern unsigned long greatest_tick_count__;

/* Help to quit cleanly when init fail at a certain level */
static int init_level = 0;

/* Prototype for Logging to help spotting errors at init */
int LogMessage(uint8_t level, char* buf, uint32_t size);

/*
 * Prototypes of functions exported by plugins
 **/
%(calls_prototypes)s

/*
 * Retrieve input variables, run PLC and publish output variables
 **/
void __run(void)
{
    __tick++;
    if (greatest_tick_count__)
        __tick %%= greatest_tick_count__;

    %(retrieve_calls)s

    /*__retrieve_debug();*/

    config_run__(__tick);

    __publish_debug();

    %(publish_calls)s

}

/*
 * Initialize variables according to PLC's default values,
 * and then init plugins with that values
 **/
int __init(int argc,char **argv)
{
    int res = 0;
    init_level = 0;
    
    /* Effective tick time with 1ms default value */
    if(!common_ticktime__)
        common_ticktime__ = 1000000;

    config_init__();
    __init_debug();
    %(init_calls)s
    return res;
}
/*
 * Calls plugin cleanup proc.
 **/
void __cleanup(void)
{
    %(cleanup_calls)s
    __cleanup_debug();
}

void PLC_GetTime(IEC_TIME *CURRENT_TIME);
void PLC_SetTimer(unsigned long long next, unsigned long long period);