Avoid usage of localized strings before initialization during import in many modules
This happens if import is done before i18n setup
(InstallLocalRessources()).
This affects PLCOpenEditor mostly. Beremiz IDE is free from this issue, but moving
initialization from import should make modules more robust.
Otherwise execution result depends on where and when import was done
and this is not a good thing.
Some modules (ConfigTreeNode, features, CodeFileEditor related
classes) still have this, but they are used only in Beremiz.
Most problems result in non-working internatialization.
In some cases (VariablePanel) there is backtrace, because localized
key is not found in non-localized dictionary.
Beremiz and Beremiz_service connectors
======================================
To connect a PLC, Beremiz provides 2 types of connectors :
* a Pyro connector
* a WAMP connector
To configure the connection, you have to set the *URI_location* in your project Config tab according to this documentation.
The Pyro connector
----------------------------
Pyro is an advanced and powerful Distributed Object Technology system written entirely in Python.
Beremiz_service spawns a Pyro server, serving a PLCObject (see runtime/PLCObject.py). Therefore, Beremiz acts as a Pyro client.
TODO:: link to PLCObject API documentation
URI_location :
* LOCAL:// is a facility that starts the PLC service locally and connect Beremiz to it via Pyro.
This is intended for use in development stage.
* PYRO://<ip:port> normal connection to a remote PLC. PLC default port is 3000.
* PYROS://<ip:port> SSL connection to a remote PLC, see below.
more information about Pyro can be found on http://pythonhosted.org//Pyro/1-intro.html
===========================
Setup a Pyro SSL connection
===========================
Pyro v3 has a limited TLS/SSL support based on m2crypto. Pyro v4 had dropped it.
In order to have a full and reliable SSL, we recommand to use a TLS/SSL wrapper as nginx, stub or stunnel.
--------------------
TLS-PSK with stunnel
--------------------
In this example, we setup a simple TLS-PSK connection according to rfc4279.
This ciphersuite avoid the need for public key operations and certificate management.
It is perfect for a performance-constrained environments with limited CPU power as a PLC.
Needed :
* stunnel >= 5.09
verify openssl support for PSK cipher::
openssl ciphers -v 'PSK'
----------------------
Client setup (Beremiz)
----------------------
You need to choose an identity for your client, here *client1*.
generate a valid and strong key::
$ echo client1:$(openssl rand -base64 48) > pskclient1.txt
write a stunnel client configuration file *stunnel-client.conf*::
output = stunnel-client.log
client = yes
[beremiz]
accept = 3002
connect = [PLC]:3001
PSKidentity = client1
PSKsecrets = pskclient1.txt
start stunnel client side::
stunnel stunnel-client.conf
You could now connect beremiz with classic URI_location = PYRO://127.0.0.1:3002
--------------------
Server setup (PLC)
--------------------
import the client key in a keyfile psk.txt, concatening all client key.
write a stunnel server configuration file *stunnel-server.conf*::
output = stunnel-server.log
[beremiz]
accept = 3001
connect = 127.0.0.1:3000
PSKsecrets = psk.txt
start stunnel server side::
stunnel stunnel-server.conf
more documentation on stunnel http://www.stunnel.org/docs.html
The WAMP connector
------------------
WAMP is an open standard WebSocket subprotocol that provides two application messaging
patterns in one unified protocol: Remote Procedure Calls + Publish & Subscribe.
Beremiz WAMP connector implementation uses Autobahn and crossbar.
URI_location :
* WAMP://127.0.0.1:8888#Automation#2534667845
more information about WAMP can be found on http://wamp.ws/