Backed out changeset ddadbdf20e70, no effect on current problem.
#!/bin/bash
rm -f ./SRVOK ./PLCOK
# Run server
$BEREMIZPYTHONPATH - > >(
echo "Start SRV loop"
while read line; do
# Wait for server to print modified value
echo "SRV>> $line"
if [[ "$line" == 3.4 ]]; then
echo "PLC could write value"
touch ./SRVOK
fi
done
echo "End SRV loop"
) << EOF &
import sys
import time
from opcua import ua, Server
server = Server()
server.set_endpoint("opc.tcp://127.0.0.1:4840/freeopcua/server/")
uri = "http://beremiz.github.io"
idx = server.register_namespace(uri)
objects = server.get_objects_node()
testobj = objects.add_object(idx, "TestObject")
testvarout = testobj.add_variable(idx, "TestOut", 1.2)
testvar = testobj.add_variable(idx, "TestIn", 5.6)
testvar.set_writable()
server.start()
try:
while True:
time.sleep(1)
print testvar.get_value()
sys.stdout.flush()
finally:
server.stop()
EOF
SERVER_PID=$!
# Start PLC with opcua test
setsid $BEREMIZPYTHONPATH $BEREMIZPATH/Beremiz_cli.py -k \
--project-home $BEREMIZPATH/tests/projects/opcua_client build transfer run > >(
echo "Start PLC loop"
while read line; do
# Wait for PLC runtime to output expected value on stdout
echo "PLC>> $line"
if [[ "$line" == 1.2 ]]; then
echo "PLC could read value"
touch ./PLCOK
fi
done
echo "End PLC loop"
) &
PLC_PID=$!
echo all subprocess started, start polling results
res=110 # default to ETIMEDOUT
c=30
while ((c--)); do
if [[ -a ./SRVOK && -a ./PLCOK ]]; then
echo got results.
res=0 # OK success
break
else
echo waiting.... $c
sleep 1
fi
done
# Kill PLC and subprocess
echo will kill PLC:$PLC_PID and SERVER:$SERVER_PID
pkill -s $PLC_PID
kill $SERVER_PID
exit $res