NativeLib.xml
author Sergey Surkov <surkovsv93@gmail.com>
Tue, 18 Oct 2016 17:44:08 +0300
changeset 1544 2969c2123105
parent 1050 56bef276055e
permissions -rw-r--r--
Fix bug with two or more wires connected to one input. Now only one wire can be connected to one input, except BOOLean signals in LD and SFC. If user trying to connect wire with already connected input, wire highlight will become red.
Signed-off-by: Andrey Skvortsov <andrej.skvortzov@gmail.com>
<?xml version="1.0" encoding="UTF-8"?>
<project xmlns="http://www.plcopen.org/xml/tc6.xsd"
         xsi:schemaLocation="http://www.plcopen.org/xml/tc6.xsd"
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xmlns:xhtml="http://www.w3.org/1999/xhtml">
  <fileHeader companyName="Unknown"
              productName="Unnamed"
              productVersion="1"
              creationDateTime="2013-01-29T14:01:00"/>
  <contentHeader name="Unnamed"
                 modificationDateTime="2013-02-26T15:59:13">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes>
      <dataType name="LOGLEVEL">
        <baseType>
          <enum>
            <values>
              <value name="CRITICAL"/>
              <value name="WARNING"/>
              <value name="INFO"/>
              <value name="DEBUG"/>
            </values>
          </enum>
        </baseType>
        <initialValue>
          <simpleValue value="INFO"/>
        </initialValue>
      </dataType>
    </dataTypes>
    <pous>
      <pou name="LOGGER" pouType="functionBlock">
        <interface>
          <inputVars>
            <variable name="TRIG">
              <type>
                <BOOL/>
              </type>
            </variable>
            <variable name="MSG">
              <type>
                <string/>
              </type>
            </variable>
            <variable name="LEVEL">
              <type>
                <derived name="LOGLEVEL"/>
              </type>
              <initialValue>
                <simpleValue value="INFO"/>
              </initialValue>
            </variable>
          </inputVars>
          <localVars>
            <variable name="TRIG0">
              <type>
                <BOOL/>
              </type>
            </variable>
          </localVars>
        </interface>
        <body>
          <ST>
<![CDATA[IF TRIG AND NOT TRIG0 THEN
{{
 LogMessage(GetFbVar(LEVEL),(char*)GetFbVar(MSG, .body),GetFbVar(MSG, .len));
}}
END_IF;
TRIG0:=TRIG;
]]>
          </ST>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations/>
  </instances>
</project>