NativeLib.xml
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Wed, 07 Dec 2016 19:28:13 +0300
changeset 1598 1445457547f7
parent 1050 56bef276055e
permissions -rw-r--r--
update PLC status after initialization

This is necessary especially if existed PLC program is loaded, but PLC
is not started automatically. In this case taskbar icon shows that PLC
isn't empty.
<?xml version="1.0" encoding="UTF-8"?>
<project xmlns="http://www.plcopen.org/xml/tc6.xsd"
         xsi:schemaLocation="http://www.plcopen.org/xml/tc6.xsd"
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xmlns:xhtml="http://www.w3.org/1999/xhtml">
  <fileHeader companyName="Unknown"
              productName="Unnamed"
              productVersion="1"
              creationDateTime="2013-01-29T14:01:00"/>
  <contentHeader name="Unnamed"
                 modificationDateTime="2013-02-26T15:59:13">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes>
      <dataType name="LOGLEVEL">
        <baseType>
          <enum>
            <values>
              <value name="CRITICAL"/>
              <value name="WARNING"/>
              <value name="INFO"/>
              <value name="DEBUG"/>
            </values>
          </enum>
        </baseType>
        <initialValue>
          <simpleValue value="INFO"/>
        </initialValue>
      </dataType>
    </dataTypes>
    <pous>
      <pou name="LOGGER" pouType="functionBlock">
        <interface>
          <inputVars>
            <variable name="TRIG">
              <type>
                <BOOL/>
              </type>
            </variable>
            <variable name="MSG">
              <type>
                <string/>
              </type>
            </variable>
            <variable name="LEVEL">
              <type>
                <derived name="LOGLEVEL"/>
              </type>
              <initialValue>
                <simpleValue value="INFO"/>
              </initialValue>
            </variable>
          </inputVars>
          <localVars>
            <variable name="TRIG0">
              <type>
                <BOOL/>
              </type>
            </variable>
          </localVars>
        </interface>
        <body>
          <ST>
<![CDATA[IF TRIG AND NOT TRIG0 THEN
{{
 LogMessage(GetFbVar(LEVEL),(char*)GetFbVar(MSG, .body),GetFbVar(MSG, .len));
}}
END_IF;
TRIG0:=TRIG;
]]>
          </ST>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations/>
  </instances>
</project>