tests/canopen_master/plc.xml
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Tue, 09 Oct 2018 11:43:39 +0300
changeset 2438 0f2e5303f212
parent 2346 ac16bad593cf
permissions -rw-r--r--
pep8, ignore W606 'async' and 'await' are reserved keywords starting with Python 3.7

This error exists in pyjs extension, but pyjs isn't going to Python3.
'noqa' isn't working for W606, so this warning is disabled completely.
'async' and 'await' are still checked by pylint.
<?xml version='1.0' encoding='utf-8'?>
<project xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.plcopen.org/xml/tc6_0201" xmlns:xhtml="http://www.w3.org/1999/xhtml" xsi:schemaLocation="http://www.plcopen.org/xml/tc6_0201">
  <fileHeader companyName="beremiz" productName="beremiz" productVersion="1" creationDateTime="2008-06-24T18:44:00"/>
  <contentHeader name="canopen_master" modificationDateTime="2018-09-26T13:31:52" language="en-US">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes/>
    <pous>
      <pou name="test_main" pouType="program">
        <interface>
          <localVars>
            <variable name="PLC_OUT" address="%QW0.0.2.8193.0">
              <type>
                <INT/>
              </type>
            </variable>
            <variable name="PLC_IN" address="%IW0.0.2.8192.0">
              <type>
                <INT/>
              </type>
            </variable>
          </localVars>
        </interface>
        <body>
          <FBD>
            <outVariable localId="1" height="29" width="80" executionOrderId="0" negated="false">
              <position x="362" y="139"/>
              <connectionPointIn>
                <relPosition x="0" y="14"/>
                <connection refLocalId="4" formalParameter="OUT">
                  <position x="362" y="153"/>
                  <position x="299" y="153"/>
                </connection>
              </connectionPointIn>
              <expression>PLC_OUT</expression>
            </outVariable>
            <inVariable localId="2" height="29" width="20">
              <position x="100" y="115"/>
              <connectionPointOut>
                <relPosition x="20" y="14"/>
              </connectionPointOut>
              <expression>1</expression>
            </inVariable>
            <block localId="4" width="75" height="60" typeName="ADD">
              <position x="224" y="123"/>
              <inputVariables>
                <variable formalParameter="IN1">
                  <connectionPointIn>
                    <relPosition x="0" y="30"/>
                    <connection refLocalId="2">
                      <position x="224" y="153"/>
                      <position x="183" y="153"/>
                      <position x="183" y="129"/>
                      <position x="120" y="129"/>
                    </connection>
                  </connectionPointIn>
                </variable>
                <variable formalParameter="IN2">
                  <connectionPointIn>
                    <relPosition x="0" y="50"/>
                    <connection refLocalId="5">
                      <position x="224" y="173"/>
                      <position x="199" y="173"/>
                      <position x="199" y="201"/>
                      <position x="174" y="201"/>
                    </connection>
                  </connectionPointIn>
                </variable>
              </inputVariables>
              <inOutVariables/>
              <outputVariables>
                <variable formalParameter="OUT">
                  <connectionPointOut>
                    <relPosition x="75" y="30"/>
                  </connectionPointOut>
                </variable>
              </outputVariables>
            </block>
            <inVariable localId="5" height="29" width="70">
              <position x="104" y="187"/>
              <connectionPointOut>
                <relPosition x="70" y="14"/>
              </connectionPointOut>
              <expression>PLC_IN</expression>
            </inVariable>
          </FBD>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations>
      <configuration name="conf">
        <resource name="res">
          <task name="tache" interval="t#50ms" priority="0">
            <pouInstance name="toto" typeName="test_main"/>
          </task>
        </resource>
      </configuration>
    </configurations>
  </instances>
</project>