1 /************************************************************************** |
|
2 * |
|
3 * Copyright (C) 2006 Steve Karg <skarg@users.sourceforge.net> |
|
4 * Copyright (C) 2017 Mario de Sousa <msousa@fe.up.pt> |
|
5 * |
|
6 * Permission is hereby granted, free of charge, to any person obtaining |
|
7 * a copy of this software and associated documentation files (the |
|
8 * "Software"), to deal in the Software without restriction, including |
|
9 * without limitation the rights to use, copy, modify, merge, publish, |
|
10 * distribute, sublicense, and/or sell copies of the Software, and to |
|
11 * permit persons to whom the Software is furnished to do so, subject to |
|
12 * the following conditions: |
|
13 * |
|
14 * The above copyright notice and this permission notice shall be included |
|
15 * in all copies or substantial portions of the Software. |
|
16 * |
|
17 * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, |
|
18 * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF |
|
19 * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. |
|
20 * IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY |
|
21 * CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, |
|
22 * TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE |
|
23 * SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. |
|
24 * |
|
25 *********************************************************************/ |
|
26 |
|
27 /* Binary Output Objects - customize for your use */ |
|
28 |
|
29 #include <stdbool.h> |
|
30 #include <stdint.h> |
|
31 #include <stdio.h> |
|
32 |
|
33 #include "config_bacnet_for_beremiz_%(locstr)s.h" /* the custom configuration for beremiz plugin */ |
|
34 #include "bacdef.h" |
|
35 #include "bacdcode.h" |
|
36 #include "bacenum.h" |
|
37 #include "bacapp.h" |
|
38 #include "wp.h" |
|
39 #include "rp.h" |
|
40 #include "bo_%(locstr)s.h" |
|
41 #include "handlers.h" |
|
42 |
|
43 /* we choose to have a NULL level in our system represented by */ |
|
44 /* a particular value. When the priorities are not in use, they */ |
|
45 /* will be relinquished (i.e. set to the NULL level). */ |
|
46 // BINARY_NULL |
|
47 /* test whether value is NULL */ |
|
48 #define BINARY_OUTPUT_IS_NULL(x) ((x) == BINARY_NULL) |
|
49 |
|
50 /* When all the priorities are level null, the present value returns |
|
51 * the Relinquish Default value |
|
52 */ |
|
53 #define BO_VALUE_RELINQUISH_DEFAULT BINARY_INACTIVE |
|
54 |
|
55 /* The IEC 61131-3 located variables mapped onto the Binary Output objects of BACnet protocol */ |
|
56 %(BO_lvars)s |
|
57 |
|
58 |
|
59 /* The array where we keep all the state related to the Binary Output Objects */ |
|
60 #define MAX_BINARY_OUTPUTS %(BO_count)s |
|
61 static BINARY_OUTPUT_DESCR BO_Descr[MAX_BINARY_OUTPUTS] = { |
|
62 %(BO_param)s |
|
63 }; |
|
64 |
|
65 |
|
66 |
|
67 |
|
68 /* These three arrays are used by the ReadPropertyMultiple handler, |
|
69 * as well as to initialize the XXX_Property_List used by the |
|
70 * Property List (PROP_PROPERTY_LIST) property. |
|
71 */ |
|
72 static const int Binary_Output_Properties_Required[] = { |
|
73 /* (1) Currently Supported */ |
|
74 /* (2) Required by standard ASHRAE 135-2016 */ |
|
75 /*(1)(2) */ |
|
76 PROP_OBJECT_IDENTIFIER, /* R R ( 75) */ |
|
77 PROP_OBJECT_NAME, /* R R ( 77) */ |
|
78 PROP_OBJECT_TYPE, /* R R ( 79) */ |
|
79 PROP_PRESENT_VALUE, /* W W ( 85) */ |
|
80 PROP_STATUS_FLAGS, /* R R (111) */ |
|
81 PROP_EVENT_STATE, /* R R ( 36) */ |
|
82 PROP_OUT_OF_SERVICE, /* W R ( 81) */ |
|
83 PROP_POLARITY, /* R R ( 84) */ |
|
84 PROP_PRIORITY_ARRAY, /* R R ( 87) */ |
|
85 PROP_RELINQUISH_DEFAULT, /* R R (104) */ |
|
86 // PROP_PROPERTY_LIST, /* R R (371) */ |
|
87 // PROP_CURRENT_COMMAND_PRIORITY,/* R R (431) */ |
|
88 -1 |
|
89 }; |
|
90 |
|
91 static const int Binary_Output_Properties_Optional[] = { |
|
92 /* (1) Currently Supported */ |
|
93 /* (2) Required by standard ASHRAE 135-2016 */ |
|
94 /*(1)(2) */ |
|
95 PROP_DESCRIPTION, /* R O ( 28) */ |
|
96 -1 |
|
97 }; |
|
98 |
|
99 static const int Binary_Output_Properties_Proprietary[] = { |
|
100 -1 |
|
101 }; |
|
102 |
|
103 |
|
104 /* This array stores the PROPERTY_LIST which may be read by clients. |
|
105 * End of list is marked by following the last element with the value '-1' |
|
106 * |
|
107 * It is initialized by Binary_Output_Init() based off the values |
|
108 * stored in Binary_Output_Properties_Required |
|
109 * Binary_Output_Properties_Optional |
|
110 * Binary_Output_Properties_Proprietary |
|
111 */ |
|
112 /* TODO: Allocate memory for this array with malloc() at startup */ |
|
113 static int Binary_Output_Properties_List[64]; |
|
114 |
|
115 |
|
116 |
|
117 |
|
118 |
|
119 /********************************************************/ |
|
120 /** Callback functions. **/ |
|
121 /** Functions required by BACnet devie implementation. **/ |
|
122 /********************************************************/ |
|
123 |
|
124 |
|
125 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
126 void Binary_Output_Property_Lists( |
|
127 const int **pRequired, |
|
128 const int **pOptional, |
|
129 const int **pProprietary) |
|
130 { |
|
131 if (pRequired) |
|
132 *pRequired = Binary_Output_Properties_Required; |
|
133 if (pOptional) |
|
134 *pOptional = Binary_Output_Properties_Optional; |
|
135 if (pProprietary) |
|
136 *pProprietary = Binary_Output_Properties_Proprietary; |
|
137 |
|
138 return; |
|
139 } |
|
140 |
|
141 |
|
142 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
143 void Binary_Output_Init( |
|
144 void) |
|
145 { |
|
146 unsigned i, j; |
|
147 static bool initialized = false; |
|
148 |
|
149 // fprintf(stderr, "BACnet plugin: Binary_Output_Init() called!\n"); |
|
150 |
|
151 if (!initialized) { |
|
152 initialized = true; |
|
153 |
|
154 /* initialize the Binary_Output_Properties_List array */ |
|
155 int len = 0; |
|
156 len += BACnet_Init_Properties_List(Binary_Output_Properties_List + len, |
|
157 Binary_Output_Properties_Required); |
|
158 len += BACnet_Init_Properties_List(Binary_Output_Properties_List + len, |
|
159 Binary_Output_Properties_Optional); |
|
160 len += BACnet_Init_Properties_List(Binary_Output_Properties_List + len, |
|
161 Binary_Output_Properties_Proprietary); |
|
162 |
|
163 /* initialize all the binary values priority arrays to NULL */ |
|
164 for (i = 0; i < MAX_BINARY_OUTPUTS; i++) { |
|
165 for (j = 0; j < BACNET_MAX_PRIORITY; j++) { |
|
166 BO_Descr[i].Present_Value[j] = BINARY_NULL; |
|
167 } |
|
168 } |
|
169 } |
|
170 |
|
171 return; |
|
172 } |
|
173 |
|
174 |
|
175 |
|
176 /* validate that the given instance (Object ID) exists */ |
|
177 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
178 bool Binary_Output_Valid_Instance( |
|
179 uint32_t object_instance) |
|
180 { |
|
181 // fprintf(stderr, "BACnet plugin: Binary_Output_Valid_Instance(obj_ID=%%u) called!\n", object _instance); |
|
182 return (Binary_Output_Instance_To_Index(object_instance) < MAX_BINARY_OUTPUTS); |
|
183 } |
|
184 |
|
185 |
|
186 /* the number of Binary Output Objects */ |
|
187 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
188 unsigned Binary_Output_Count(void) {return MAX_BINARY_OUTPUTS;} |
|
189 |
|
190 |
|
191 /* returns the instance (i.e. Object Identifier) that correlates to the correct index */ |
|
192 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
193 uint32_t Binary_Output_Index_To_Instance(unsigned index) {return BO_Descr[index].Object_Identifier;} |
|
194 |
|
195 |
|
196 /* returns the index that correlates to the correct instance number (Object Identifier) */ |
|
197 unsigned Binary_Output_Instance_To_Index( |
|
198 uint32_t object_instance) |
|
199 { |
|
200 unsigned index = 0; |
|
201 |
|
202 for (index = 0; index < MAX_BINARY_OUTPUTS; index++) |
|
203 if (object_instance == BO_Descr[index].Object_Identifier) |
|
204 return index; |
|
205 |
|
206 /* error, this object ID is not in our list! */ |
|
207 return MAX_BINARY_OUTPUTS; |
|
208 } |
|
209 |
|
210 |
|
211 |
|
212 BACNET_BINARY_PV Binary_Output_Present_Value( |
|
213 uint32_t object_instance) |
|
214 { |
|
215 BACNET_BINARY_PV value = BO_VALUE_RELINQUISH_DEFAULT; |
|
216 unsigned index = 0; |
|
217 unsigned i = 0; |
|
218 |
|
219 // fprintf(stderr, "BACnet plugin: Binary_Output_Present_Value(obj_ID=%%u) called!\n", object_instance); |
|
220 |
|
221 index = Binary_Output_Instance_To_Index(object_instance); |
|
222 if (index < MAX_BINARY_OUTPUTS) { |
|
223 for (i = 0; i < BACNET_MAX_PRIORITY; i++) { |
|
224 if (!BINARY_OUTPUT_IS_NULL(BO_Descr[index].Present_Value[i])) { |
|
225 value = BO_Descr[index].Present_Value[i]; |
|
226 break; |
|
227 } |
|
228 } |
|
229 } |
|
230 |
|
231 return value; |
|
232 } |
|
233 |
|
234 |
|
235 |
|
236 /* returns command priority (1..16), or 0 if all priority values are at NULL */ |
|
237 int Binary_Output_Current_Command_Priority( |
|
238 uint32_t object_instance) |
|
239 { |
|
240 unsigned index = 0; |
|
241 unsigned i = 0; |
|
242 |
|
243 index = Binary_Output_Instance_To_Index(object_instance); |
|
244 if (index < MAX_BINARY_OUTPUTS) { |
|
245 for (i = 0; i < BACNET_MAX_PRIORITY; i++) { |
|
246 if (!BINARY_OUTPUT_IS_NULL(BO_Descr[index].Present_Value[i])) { |
|
247 return i+1; // +1 since priority is 1..16, and not 0..15 |
|
248 } |
|
249 } |
|
250 } |
|
251 // command values in all priorities are set to NULL |
|
252 return 0; |
|
253 } |
|
254 |
|
255 |
|
256 |
|
257 /* note: the object name must be unique within this device */ |
|
258 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
259 bool Binary_Output_Object_Name( |
|
260 uint32_t object_instance, |
|
261 BACNET_CHARACTER_STRING * object_name) |
|
262 { |
|
263 bool status = false; |
|
264 unsigned index = Binary_Output_Instance_To_Index(object_instance); |
|
265 |
|
266 if (index < MAX_BINARY_OUTPUTS) |
|
267 status = characterstring_init_ansi(object_name, BO_Descr[index].Object_Name); |
|
268 |
|
269 return status; |
|
270 } |
|
271 |
|
272 |
|
273 |
|
274 bool Binary_Output_Object_Description( |
|
275 uint32_t object_instance, |
|
276 BACNET_CHARACTER_STRING * object_name) |
|
277 { |
|
278 bool status = false; |
|
279 unsigned index = Binary_Output_Instance_To_Index(object_instance); |
|
280 |
|
281 if (index < MAX_BINARY_OUTPUTS) |
|
282 status = characterstring_init_ansi(object_name, BO_Descr[index].Description); |
|
283 |
|
284 return status; |
|
285 } |
|
286 |
|
287 |
|
288 |
|
289 /* return apdu len, or BACNET_STATUS_ERROR on error */ |
|
290 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
291 int Binary_Output_Read_Property( |
|
292 BACNET_READ_PROPERTY_DATA * rpdata) |
|
293 { |
|
294 int len = 0; |
|
295 int apdu_len = 0; /* return value */ |
|
296 BACNET_BIT_STRING bit_string; |
|
297 BACNET_CHARACTER_STRING char_string; |
|
298 BACNET_BINARY_PV present_value = BINARY_INACTIVE; |
|
299 unsigned object_index = 0; |
|
300 unsigned i = 0; |
|
301 bool state = false; |
|
302 uint8_t *apdu = NULL; |
|
303 |
|
304 // fprintf(stderr, "BACnet plugin: Binary_Output_Read_Property() called!\n"); |
|
305 |
|
306 if ((rpdata == NULL) || (rpdata->application_data == NULL) || |
|
307 (rpdata->application_data_len == 0)) { |
|
308 return 0; |
|
309 } |
|
310 |
|
311 object_index = Binary_Output_Instance_To_Index(rpdata->object_instance); |
|
312 if (object_index >= MAX_BINARY_OUTPUTS) { |
|
313 rpdata->error_class = ERROR_CLASS_OBJECT; |
|
314 rpdata->error_code = ERROR_CODE_UNKNOWN_OBJECT; |
|
315 return BACNET_STATUS_ERROR; |
|
316 } |
|
317 |
|
318 apdu = rpdata->application_data; |
|
319 switch (rpdata->object_property) { |
|
320 case PROP_OBJECT_IDENTIFIER: |
|
321 apdu_len = |
|
322 encode_application_object_id(&apdu[0], OBJECT_BINARY_OUTPUT, |
|
323 rpdata->object_instance); |
|
324 break; |
|
325 case PROP_OBJECT_NAME: |
|
326 Binary_Output_Object_Name(rpdata->object_instance, &char_string); |
|
327 apdu_len = |
|
328 encode_application_character_string(&apdu[0], &char_string); |
|
329 break; |
|
330 case PROP_DESCRIPTION: |
|
331 Binary_Output_Object_Description(rpdata->object_instance, &char_string); |
|
332 apdu_len = |
|
333 encode_application_character_string(&apdu[0], &char_string); |
|
334 break; |
|
335 case PROP_OBJECT_TYPE: |
|
336 apdu_len = |
|
337 encode_application_enumerated(&apdu[0], OBJECT_BINARY_OUTPUT); |
|
338 break; |
|
339 case PROP_PRESENT_VALUE: |
|
340 present_value = |
|
341 Binary_Output_Present_Value(rpdata->object_instance); |
|
342 apdu_len = encode_application_enumerated(&apdu[0], present_value); |
|
343 break; |
|
344 case PROP_STATUS_FLAGS: |
|
345 /* note: see the details in the standard on how to use these */ |
|
346 bitstring_init(&bit_string); |
|
347 bitstring_set_bit(&bit_string, STATUS_FLAG_IN_ALARM, false); |
|
348 bitstring_set_bit(&bit_string, STATUS_FLAG_FAULT, false); |
|
349 bitstring_set_bit(&bit_string, STATUS_FLAG_OVERRIDDEN, false); |
|
350 state = BO_Descr[object_index].Out_Of_Service; |
|
351 bitstring_set_bit(&bit_string, STATUS_FLAG_OUT_OF_SERVICE, state); |
|
352 apdu_len = encode_application_bitstring(&apdu[0], &bit_string); |
|
353 break; |
|
354 case PROP_EVENT_STATE: |
|
355 /* note: see the details in the standard on how to use this */ |
|
356 apdu_len = |
|
357 encode_application_enumerated(&apdu[0], EVENT_STATE_NORMAL); |
|
358 break; |
|
359 case PROP_OUT_OF_SERVICE: |
|
360 state = BO_Descr[object_index].Out_Of_Service; |
|
361 apdu_len = encode_application_boolean(&apdu[0], state); |
|
362 break; |
|
363 case PROP_PRIORITY_ARRAY: |
|
364 BACnet_encode_array(BO_Descr[object_index].Present_Value, |
|
365 BACNET_MAX_PRIORITY, |
|
366 BINARY_OUTPUT_IS_NULL, |
|
367 encode_application_enumerated) |
|
368 break; |
|
369 // case PROP_CURRENT_COMMAND_PRIORITY: { |
|
370 // unsigned i = Binary_Output_Current_Command_Priority(rpdata->object_instance); |
|
371 // if (i == 0) apdu_len = encode_application_null (&apdu[0]); |
|
372 // else apdu_len = encode_application_unsigned(&apdu[0], i); |
|
373 // break; |
|
374 // } |
|
375 |
|
376 case PROP_RELINQUISH_DEFAULT: |
|
377 present_value = BO_VALUE_RELINQUISH_DEFAULT; |
|
378 apdu_len = encode_application_enumerated(&apdu[0], present_value); |
|
379 break; |
|
380 case PROP_POLARITY: |
|
381 apdu_len = encode_application_enumerated(&apdu[0], |
|
382 BO_Descr[object_index].Polarity); |
|
383 break; |
|
384 // case PROP_PROPERTY_LIST: |
|
385 // BACnet_encode_array(Binary_Output_Properties_List, |
|
386 // property_list_count(Binary_Output_Properties_List), |
|
387 // retfalse, encode_application_enumerated); |
|
388 // break; |
|
389 default: |
|
390 rpdata->error_class = ERROR_CLASS_PROPERTY; |
|
391 rpdata->error_code = ERROR_CODE_UNKNOWN_PROPERTY; |
|
392 apdu_len = BACNET_STATUS_ERROR; |
|
393 break; |
|
394 } |
|
395 /* only array properties can have array options */ |
|
396 if ((apdu_len >= 0) && (rpdata->object_property != PROP_PRIORITY_ARRAY) && |
|
397 // (rpdata->object_property != PROP_PROPERTY_LIST) && |
|
398 (rpdata->array_index != BACNET_ARRAY_ALL)) { |
|
399 rpdata->error_class = ERROR_CLASS_PROPERTY; |
|
400 rpdata->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY; |
|
401 apdu_len = BACNET_STATUS_ERROR; |
|
402 } |
|
403 |
|
404 return apdu_len; |
|
405 } |
|
406 |
|
407 |
|
408 |
|
409 |
|
410 /* returns true if successful */ |
|
411 /* This is a callback function. Callback set in My_Object_Table[] array declared in device.c, */ |
|
412 bool Binary_Output_Write_Property( |
|
413 BACNET_WRITE_PROPERTY_DATA * wp_data) |
|
414 { |
|
415 bool status = false; /* return value */ |
|
416 unsigned int object_index = 0; |
|
417 unsigned int priority = 0; |
|
418 BACNET_BINARY_PV level = BINARY_NULL; |
|
419 int len = 0; |
|
420 BACNET_APPLICATION_DATA_VALUE value; |
|
421 |
|
422 /* decode the some of the request */ |
|
423 len = |
|
424 bacapp_decode_application_data(wp_data->application_data, |
|
425 wp_data->application_data_len, &value); |
|
426 /* FIXME: len < application_data_len: more data? */ |
|
427 if (len < 0) { |
|
428 /* error while decoding - a value larger than we can handle */ |
|
429 wp_data->error_class = ERROR_CLASS_PROPERTY; |
|
430 wp_data->error_code = ERROR_CODE_VALUE_OUT_OF_RANGE; |
|
431 return false; |
|
432 } |
|
433 /* only array properties can have array options */ |
|
434 if ((wp_data->object_property != PROP_PRIORITY_ARRAY) && |
|
435 (wp_data->array_index != BACNET_ARRAY_ALL)) { |
|
436 wp_data->error_class = ERROR_CLASS_PROPERTY; |
|
437 wp_data->error_code = ERROR_CODE_PROPERTY_IS_NOT_AN_ARRAY; |
|
438 return false; |
|
439 } |
|
440 /* No need to check whether object_index is within bounds. |
|
441 * Has already been checked before Binary_Output_Write_Property() is called |
|
442 */ |
|
443 object_index = Binary_Output_Instance_To_Index(wp_data->object_instance); |
|
444 |
|
445 switch (wp_data->object_property) { |
|
446 case PROP_PRESENT_VALUE: |
|
447 if (value.tag == BACNET_APPLICATION_TAG_ENUMERATED) { |
|
448 priority = wp_data->priority; |
|
449 if (priority && (priority <= BACNET_MAX_PRIORITY) && |
|
450 (priority != 6 /* reserved */ ) && |
|
451 (value.type.Enumerated <= MAX_BINARY_PV)) { |
|
452 level = (BACNET_BINARY_PV) value.type.Enumerated; |
|
453 priority--; |
|
454 BO_Descr[object_index].Present_Value[priority] = level; |
|
455 status = true; |
|
456 } else if (priority == 6) { |
|
457 /* Command priority 6 is reserved for use by Minimum On/Off |
|
458 algorithm and may not be used for other purposes in any |
|
459 object. */ |
|
460 wp_data->error_class = ERROR_CLASS_PROPERTY; |
|
461 wp_data->error_code = ERROR_CODE_WRITE_ACCESS_DENIED; |
|
462 } else { |
|
463 wp_data->error_class = ERROR_CLASS_PROPERTY; |
|
464 wp_data->error_code = ERROR_CODE_VALUE_OUT_OF_RANGE; |
|
465 } |
|
466 } else { |
|
467 status = |
|
468 WPValidateArgType(&value, BACNET_APPLICATION_TAG_NULL, |
|
469 &wp_data->error_class, &wp_data->error_code); |
|
470 if (status) { |
|
471 level = BINARY_NULL; |
|
472 priority = wp_data->priority; |
|
473 if (priority && (priority <= BACNET_MAX_PRIORITY)) { |
|
474 priority--; |
|
475 BO_Descr[object_index].Present_Value[priority] = level; |
|
476 } else { |
|
477 status = false; |
|
478 wp_data->error_class = ERROR_CLASS_PROPERTY; |
|
479 wp_data->error_code = ERROR_CODE_VALUE_OUT_OF_RANGE; |
|
480 } |
|
481 } |
|
482 } |
|
483 break; |
|
484 case PROP_OUT_OF_SERVICE: |
|
485 { |
|
486 bool Previous_Out_Of_Service = BO_Descr[object_index].Out_Of_Service; |
|
487 status = |
|
488 WPValidateArgType(&value, BACNET_APPLICATION_TAG_BOOLEAN, |
|
489 &wp_data->error_class, &wp_data->error_code); |
|
490 if (status) { |
|
491 BO_Descr[object_index].Out_Of_Service = value.type.Boolean; |
|
492 if (Previous_Out_Of_Service && !BO_Descr[object_index].Out_Of_Service) |
|
493 /* We have just changed from Out_of_Service -> In Service */ |
|
494 /* We need to update the Present_Value to the value |
|
495 * currently in the PLC... |
|
496 */ |
|
497 BO_Descr[object_index].Present_Value[BACNET_MAX_PRIORITY-1] = |
|
498 *(BO_Descr[object_index].Located_Var_ptr); |
|
499 } |
|
500 break; |
|
501 } |
|
502 case PROP_OBJECT_IDENTIFIER: |
|
503 case PROP_OBJECT_NAME: |
|
504 case PROP_DESCRIPTION: |
|
505 case PROP_OBJECT_TYPE: |
|
506 case PROP_STATUS_FLAGS: |
|
507 case PROP_EVENT_STATE: |
|
508 case PROP_PRIORITY_ARRAY: |
|
509 // case PROP_CURRENT_COMMAND_PRIORITY: |
|
510 case PROP_RELINQUISH_DEFAULT: |
|
511 case PROP_POLARITY: |
|
512 // case PROP_PROPERTY_LIST: |
|
513 wp_data->error_class = ERROR_CLASS_PROPERTY; |
|
514 wp_data->error_code = ERROR_CODE_WRITE_ACCESS_DENIED; |
|
515 break; |
|
516 default: |
|
517 wp_data->error_class = ERROR_CLASS_PROPERTY; |
|
518 wp_data->error_code = ERROR_CODE_UNKNOWN_PROPERTY; |
|
519 break; |
|
520 } |
|
521 |
|
522 return status; |
|
523 } |
|
524 |
|
525 |
|
526 |
|
527 |
|
528 |
|
529 /********************************************/ |
|
530 /** Functions required for Beremiz plugin **/ |
|
531 /********************************************/ |
|
532 |
|
533 |
|
534 |
|
535 void Binary_Output_Copy_Present_Value_to_Located_Var(void) { |
|
536 unsigned i; |
|
537 for (i = 0; i < MAX_BINARY_OUTPUTS; i++) { |
|
538 // decouple PLC's Located Variable from Bacnet Object's Present Value if Out_Of_Service is true |
|
539 if (BO_Descr[i].Out_Of_Service) |
|
540 continue; |
|
541 |
|
542 // copy the value |
|
543 *(BO_Descr[i].Located_Var_ptr) = Binary_Output_Present_Value(BO_Descr[i].Object_Identifier); |
|
544 } |
|
545 } |
|
546 |
|
547 void Binary_Output_Copy_Located_Var_to_Present_Value(void) { |
|
548 unsigned i; |
|
549 for (i = 0; i < MAX_BINARY_OUTPUTS; i++) { |
|
550 // decouple PLC's Located Variable from Bacnet Object's Present Value if Out_Of_Service is true |
|
551 if (BO_Descr[i].Out_Of_Service) |
|
552 continue; |
|
553 |
|
554 // copy the value |
|
555 BO_Descr[i].Present_Value[BACNET_MAX_PRIORITY-1] = *(BO_Descr[i].Located_Var_ptr); |
|
556 |
|
557 // If the Present_Value was set to an invalid value (i.e. > 1, and < BINARY_NULL) |
|
558 // then we set it to BINARY_ACTIVE |
|
559 // (i.e. we assume 0 is FALSE, all other non NULL values are TRUE) |
|
560 if ((BO_Descr[i].Present_Value[BACNET_MAX_PRIORITY-1] != BINARY_INACTIVE) && |
|
561 (BO_Descr[i].Present_Value[BACNET_MAX_PRIORITY-1] != BINARY_ACTIVE ) && |
|
562 (BO_Descr[i].Present_Value[BACNET_MAX_PRIORITY-1] != BINARY_NULL )) |
|
563 BO_Descr[i].Present_Value[BACNET_MAX_PRIORITY-1] = BINARY_ACTIVE; |
|
564 } |
|
565 } |
|
566 |
|
567 |