Fix error about missing attribute 'timeout' that happens sometimes during compilation
The fix [1476:49f1763a5613] of the problem with following trace was wrong.
Traceback (most recent call last):
File "./Beremiz.py", line 1229, in run_with_except_hook
run_old(*args, **kw)
File
"/home/developer/WorkData/PLC/beremiz/beremiz/util/ProcessLogger.py",
line 68, in run
self.endcallback(self.Proc.pid, err)
File
"/home/developer/WorkData/PLC/beremiz/beremiz/util/ProcessLogger.py",
line 169, in finish
if self.timeout: self.timeout.cancel()
AttributeError: ProcessLogger instance has no attribute 'timeout'
The problem was that compilation process was finished before the timeout attribute is set.
Now timeout is set before launcing of compilation process.
367
a76ee5307bb7
Adding support for python plugin wxglade_hmi allowing creation of PLC HMI using wxglade
laurent
parents:
diff
changeset
|
1 |
WxGlade HMI |