tests/wxHMI/HMI@wxglade_hmi/baseconfnode.xml
author |
Andrey Skvortsov <andrej.skvortzov@gmail.com> |
|
Fri, 25 May 2018 18:34:05 +0300 |
changeset 2168 |
a66062a205ae |
parent 1465 |
9011e2ceea85
|
permissions |
-rw-r--r-- |
Build by default with optimization level -O2 for GCC
before -O0 was used by default, that caused pretty bad performance.
Amd64, i6700k, 4200MHz, GNU/Linux (non-RT kernel), gcc 7.2.0
-------------------------------------
Optimization | EN/ENO |no EN/ENO |
-------------------------------------
default | 11 | 9.5 |
-O3 | 3.9 | 5.2 |
-O2 | 4 | 4.8 |
-Os | 4.1 | 3.5 |
-Ofast | 3.9 | 5.2 |
-------------------------------------
ARM, BBB Cortex-A8, 600Mhz, GNU/Linux, gcc 4.6.3
-------------------------------------
Optimization | EN/ENO |no EN/ENO |
-------------------------------------
default | 273 | 226 |
-O3 | 141.8 | 106.2 |
-O2 | 142 | 107 |
-Os | 152.5 | 112.2 |
-Ofast | 141.7 | 106.2 |
-------------------------------------
For embedded systems with size constaints (like Cortex-Mx, AVR and so
on) I usually use -Os. It gets pretty good results. For
GNU/Linux-based systems -O2 is usually a good choice, as you see the
test results.
1465
9011e2ceea85
Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant
diff
changeset
|
1 |
<?xml version='1.0' encoding='utf-8'?>
|
9011e2ceea85
Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant
diff
changeset
|
2 |
<BaseParams Name="HMI" IEC_Channel="0"/>
|