Fix crash if LD input contact isn't connected
Traceback (most recent call last):
File "/home/developer/WorkData/PLC/beremiz/beremiz/BeremizIDE.py", line 339, in OnMethod
obj.CTR.CallMethod('_'+meth)
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 1996, in CallMethod
getattr(self, method)()
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 1134, in _Build
IECGenRes = self._Generate_SoftPLC()
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 746, in _Generate_SoftPLC
if self._Generate_PLC_ST():
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 763, in _Generate_PLC_ST
self._getIECgeneratedcodepath())
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCControler.py", line 456, in GenerateProgram
self.ProgramChunks = GenerateCurrentProgram(self, self.Project, errors, warnings)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1762, in GenerateCurrentProgram
generator.GenerateProgram()
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 478, in GenerateProgram
self.GeneratePouProgram(pou_name)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 260, in GeneratePouProgram
program = pou_program.GenerateProgram(pou)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1718, in GenerateProgram
self.ComputeProgram(pou)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1028, in ComputeProgram
self.GenerateBlock(instance, block_infos, body, None)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1144, in GenerateBlock
expression = self.ComputeExpression(body, connections, executionOrderId > 0)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1373, in ComputeExpression
paths = self.GeneratePaths(connections, body, order, to_inout)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1344, in GeneratePaths
elif isinstance(result[0], list):
IndexError: list index out of range
Close #70
1439
a68cd4253259
Added stub code for runtime WAMP client. Added runtime command line switch to select WAMP url and Nevow web site port. Web port is now fixed, next port number is not tested if bind fails.
Edouard Tisserant
parents:
diff
changeset
|
1 |
<?xml version='1.0' encoding='utf-8'?>
|
2288
|
2 |
<BeremizRoot xmlns:xsd="http://www.w3.org/2001/XMLSchema" URI_location="WAMP://127.0.0.1:8888#Automation#wamptest">
|
1439
a68cd4253259
Added stub code for runtime WAMP client. Added runtime command line switch to select WAMP url and Nevow web site port. Web port is now fixed, next port number is not tested if bind fails.
Edouard Tisserant
parents:
diff
changeset
|
3 |
<TargetType/>
|
a68cd4253259
Added stub code for runtime WAMP client. Added runtime command line switch to select WAMP url and Nevow web site port. Web port is now fixed, next port number is not tested if bind fails.
Edouard Tisserant
parents:
diff
changeset
|
4 |
</BeremizRoot>
|