tests/wxHMI/beremiz.xml
author Andrey Skvortsov <andrej.skvortzov@gmail.com>
Tue, 12 Sep 2017 16:49:35 +0300
changeset 1800 1711339585ce
parent 1465 9011e2ceea85
child 2231 7d87a0f98345
permissions -rw-r--r--
make possible to turn off at compile time online debugging, logging
and external sync functionality

Defines TARGET_DEBUG_DISABLE, TARGET_LOGGING_DISABLE, TARGET_EXT_SYNC_DISABLE
allow to use generated PLC code in low-cost microcontrollers,
integrate into external programs and so on.

main.c:
extern void __run(void);
int main(void)
{
for(;;) {
__run();
// sleep common_ticktime__ ns
// add common_ticktime__ ns to __CURRENT_TIME
}
return 0;
}

Compile for example for arm bare-metal:
../build$ arm-none-eabi-gcc \
-DTARGET_DEBUG_DISABLE -DTARGET_LOGGER_DISABLE
-DTARGET_EXT_SYNC_DISABLE \
-flto -ffunction-sections -fdata-sections -I../../../../matiec/lib/C \
*.c \
-nodefaultlibs --specs=nano.specs -Wl,--static -Wl,--gc-section -Wl,--start-group -lc -lm -lnosys -lgcc -Wl,--end-group
1465
9011e2ceea85 Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant
parents: 1461
diff changeset
     1
<?xml version='1.0' encoding='utf-8'?>
9011e2ceea85 Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant
parents: 1461
diff changeset
     2
<BeremizRoot URI_location="LOCAL://">
9011e2ceea85 Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant
parents: 1461
diff changeset
     3
  <TargetType/>
9011e2ceea85 Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant
parents: 1461
diff changeset
     4
  <Libraries Enable_SVGUI_Library="false"/>
9011e2ceea85 Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant
parents: 1461
diff changeset
     5
</BeremizRoot>