Mon, 29 Jun 2020 14:38:04 +0200 |
Edouard Tisserant |
Modbus: fix strange side effect of re-use of condition variables or mutex with Xenomai : without bzero of the associated types, mutex keeps locked.
|
changeset |
files
|
Wed, 24 Jun 2020 14:38:11 +0200 |
Edouard Tisserant |
Modbus: fix client timer invalid arguments.
|
changeset |
files
|
Tue, 23 Jun 2020 13:50:21 +0200 |
Edouard Tisserant |
Modbus add a timer thread, and switch timer to SIGEV_THREAD_ID to follow xenomai posix skin restrictions.
|
changeset |
files
|
Fri, 19 Jun 2020 11:07:25 +0200 |
Edouard Tisserant |
Runtime: Fix typo in PLCObject leading to exception when reporting failure.
|
changeset |
files
|
Thu, 18 Jun 2020 14:18:16 +0200 |
Edouard Tisserant |
Py_ext: use non-derived type when generating C code for handling Python PLC globals.
|
changeset |
files
|
Wed, 17 Jun 2020 14:32:55 +0200 |
Edouard Tisserant |
tests/python : add some STRING PLC Python globals with OnChange.
|
changeset |
files
|
Wed, 17 Jun 2020 14:30:55 +0200 |
Edouard Tisserant |
Runtime: STRING type for Python PLC Globals was making problem with strings, since generated code wasn't doing comparison properly.
|
changeset |
files
|
Tue, 16 Jun 2020 15:53:52 +0200 |
Tomaz Orac |
Merge
|
changeset |
files
|