Fri, 19 Apr 2019 13:11:42 +0200 Edouard Tisserant Avoid loading PLC at startup when autostart is not set in command line. As a side effect PLC status is artificially set to Stopped, and StartPLC eventually loads PLC if it is not already loaded.
Fri, 19 Apr 2019 10:53:02 +0200 Edouard Tisserant Add Repair() to WAMP interface
Thu, 18 Apr 2019 14:42:23 +0200 Edouard Tisserant Merged fix_PLC_runtime_shutdown
Thu, 18 Apr 2019 14:41:21 +0200 Edouard Tisserant Close fix_PLC_runtime_shutdown fix_PLC_runtime_shutdown
Thu, 18 Apr 2019 14:35:42 +0200 Edouard Tisserant Runtime worker : unblock the last waiting job and prevent any new job to wait when Main Worker is being shut down. fix_PLC_runtime_shutdown
Thu, 18 Apr 2019 14:34:22 +0200 Edouard Tisserant Add some "pipe to self" trick in Pyro server to accelerate runtime shutdown instead of waiting for arbitrary pyro timeout. fix_PLC_runtime_shutdown
Thu, 18 Apr 2019 14:32:43 +0200 Edouard Tisserant If call to GetPLCstatus can't be executed in PLC, then obtained status is disconnected. Status on "None" is not relevant anymore, and is replaced by Disconnected. fix_PLC_runtime_shutdown
Thu, 18 Apr 2019 14:29:55 +0200 Edouard Tisserant Enure that all threads are joined before trying to exit fix_PLC_runtime_shutdown
Wed, 17 Apr 2019 14:18:22 +0200 Edouard Tisserant Named runtime's threads to ease debugging
Wed, 17 Apr 2019 14:15:39 +0200 Edouard Tisserant Added Repair() png icon
Tue, 16 Apr 2019 14:45:41 +0200 Edouard Tisserant pep8 again...
Tue, 16 Apr 2019 13:32:32 +0200 Edouard Tisserant PEP8 fix : ./connectors/PYRO/PSK_Adapter.py:49:1: E302 expected 2 blank lines, found 1
Tue, 16 Apr 2019 11:26:52 +0200 Edouard Tisserant Added RepairPLC() to PLCObject. For now just calling PurgePLC and quit PLC runtime.
Tue, 16 Apr 2019 11:26:34 +0200 Edouard Tisserant Ensure Beremiz_service.py quits properly when Main Worker stops and wa are using Wx and/or Twisted.
Mon, 15 Apr 2019 13:34:09 +0200 Edouard Tisserant Added PurgePLC() method to PLCObject, to be invoked when PLC Status is broken. It clears PLC shared object an extra files and force status to Empty. Added correponding Repair button to toolbar, visible only when PLC status is broken.
Thu, 11 Apr 2019 13:45:27 +0200 Edouard Tisserant Background erase of debug variable panel was disabled for some reason, and it not anymore compatible with EVT_PAINT based refresh. It was leaving traces behind when removing traced variable. Fixed.