Fri, 19 Apr 2019 13:11:42 +0200 |
Edouard Tisserant |
Avoid loading PLC at startup when autostart is not set in command line. As a side effect PLC status is artificially set to Stopped, and StartPLC eventually loads PLC if it is not already loaded.
|
changeset |
files
|
Fri, 19 Apr 2019 10:53:02 +0200 |
Edouard Tisserant |
Add Repair() to WAMP interface
|
changeset |
files
|
Thu, 18 Apr 2019 14:42:23 +0200 |
Edouard Tisserant |
Merged fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:41:21 +0200 |
Edouard Tisserant |
Close fix_PLC_runtime_shutdown
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:35:42 +0200 |
Edouard Tisserant |
Runtime worker : unblock the last waiting job and prevent any new job to wait when Main Worker is being shut down.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:34:22 +0200 |
Edouard Tisserant |
Add some "pipe to self" trick in Pyro server to accelerate runtime shutdown instead of waiting for arbitrary pyro timeout.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:32:43 +0200 |
Edouard Tisserant |
If call to GetPLCstatus can't be executed in PLC, then obtained status is disconnected. Status on "None" is not relevant anymore, and is replaced by Disconnected.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:29:55 +0200 |
Edouard Tisserant |
Enure that all threads are joined before trying to exit
fix_PLC_runtime_shutdown
|
changeset |
files
|
Wed, 17 Apr 2019 14:18:22 +0200 |
Edouard Tisserant |
Named runtime's threads to ease debugging
|
changeset |
files
|
Wed, 17 Apr 2019 14:15:39 +0200 |
Edouard Tisserant |
Added Repair() png icon
|
changeset |
files
|
Tue, 16 Apr 2019 14:45:41 +0200 |
Edouard Tisserant |
pep8 again...
|
changeset |
files
|
Tue, 16 Apr 2019 13:32:32 +0200 |
Edouard Tisserant |
PEP8 fix : ./connectors/PYRO/PSK_Adapter.py:49:1: E302 expected 2 blank lines, found 1
|
changeset |
files
|
Tue, 16 Apr 2019 11:26:52 +0200 |
Edouard Tisserant |
Added RepairPLC() to PLCObject. For now just calling PurgePLC and quit PLC runtime.
|
changeset |
files
|
Tue, 16 Apr 2019 11:26:34 +0200 |
Edouard Tisserant |
Ensure Beremiz_service.py quits properly when Main Worker stops and wa are using Wx and/or Twisted.
|
changeset |
files
|
Mon, 15 Apr 2019 13:34:09 +0200 |
Edouard Tisserant |
Added PurgePLC() method to PLCObject, to be invoked when PLC Status is broken. It clears PLC shared object an extra files and force status to Empty. Added correponding Repair button to toolbar, visible only when PLC status is broken.
|
changeset |
files
|