Tue, 18 Jun 2019 14:03:08 +0200 |
Edouard Tisserant |
Removed debug code and closed branch
fix_fb_resize_wire_bug
|
changeset |
files
|
Tue, 18 Jun 2019 13:58:45 +0200 |
Edouard Tisserant |
GraphicCommons.py : Wire.SetPoints() move filtering before computation of Start and End points to avoid setting them with arbitrary directions.
fix_fb_resize_wire_bug
|
changeset |
files
|
Tue, 18 Jun 2019 09:38:20 +0200 |
Edouard Tisserant |
GraphicCommons.py : rewrote Wire.Setpoints.
fix_fb_resize_wire_bug
|
changeset |
files
|
Thu, 13 Jun 2019 15:49:48 +0200 |
Edouard Tisserant |
'Change POU Type To' becomes 'Duplicate as...', avoiding side effects of type change when POU is already instanciated. Also remove leftover returType tag in ex-function POUs, triggering exceptions at build time.
|
changeset |
files
|
Thu, 06 Jun 2019 14:03:16 +0200 |
Edouard Tisserant |
Fix PLCObject's purge failing silently with extra_files.
|
changeset |
files
|
Thu, 30 May 2019 11:53:13 +0200 |
Edouard Tisserant |
LogMessage shouldn't be serialized (can lead to blocking in case of exception in main thread), and do not require it.
|
changeset |
files
|
Thu, 30 May 2019 11:51:56 +0200 |
Edouard Tisserant |
Fixed typo leading to some exception in some rare corner cases in worker.py
|
changeset |
files
|
Tue, 23 Apr 2019 11:01:35 +0200 |
Edouard Tisserant |
Added missing 'path' field to WAMP addresses in URI editor.
|
changeset |
files
|
Tue, 23 Apr 2019 11:00:37 +0200 |
Edouard Tisserant |
Fixed exception when using URI editor for PYRO addresses
|
changeset |
files
|
Fri, 19 Apr 2019 13:11:42 +0200 |
Edouard Tisserant |
Avoid loading PLC at startup when autostart is not set in command line. As a side effect PLC status is artificially set to Stopped, and StartPLC eventually loads PLC if it is not already loaded.
|
changeset |
files
|
Fri, 19 Apr 2019 10:53:02 +0200 |
Edouard Tisserant |
Add Repair() to WAMP interface
|
changeset |
files
|
Thu, 18 Apr 2019 14:42:23 +0200 |
Edouard Tisserant |
Merged fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:41:21 +0200 |
Edouard Tisserant |
Close fix_PLC_runtime_shutdown
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:35:42 +0200 |
Edouard Tisserant |
Runtime worker : unblock the last waiting job and prevent any new job to wait when Main Worker is being shut down.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:34:22 +0200 |
Edouard Tisserant |
Add some "pipe to self" trick in Pyro server to accelerate runtime shutdown instead of waiting for arbitrary pyro timeout.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:32:43 +0200 |
Edouard Tisserant |
If call to GetPLCstatus can't be executed in PLC, then obtained status is disconnected. Status on "None" is not relevant anymore, and is replaced by Disconnected.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:29:55 +0200 |
Edouard Tisserant |
Enure that all threads are joined before trying to exit
fix_PLC_runtime_shutdown
|
changeset |
files
|
Wed, 17 Apr 2019 14:18:22 +0200 |
Edouard Tisserant |
Named runtime's threads to ease debugging
|
changeset |
files
|
Wed, 17 Apr 2019 14:15:39 +0200 |
Edouard Tisserant |
Added Repair() png icon
|
changeset |
files
|
Tue, 16 Apr 2019 14:45:41 +0200 |
Edouard Tisserant |
pep8 again...
|
changeset |
files
|
Tue, 16 Apr 2019 13:32:32 +0200 |
Edouard Tisserant |
PEP8 fix : ./connectors/PYRO/PSK_Adapter.py:49:1: E302 expected 2 blank lines, found 1
|
changeset |
files
|
Tue, 16 Apr 2019 11:26:52 +0200 |
Edouard Tisserant |
Added RepairPLC() to PLCObject. For now just calling PurgePLC and quit PLC runtime.
|
changeset |
files
|
Tue, 16 Apr 2019 11:26:34 +0200 |
Edouard Tisserant |
Ensure Beremiz_service.py quits properly when Main Worker stops and wa are using Wx and/or Twisted.
|
changeset |
files
|
Mon, 15 Apr 2019 13:34:09 +0200 |
Edouard Tisserant |
Added PurgePLC() method to PLCObject, to be invoked when PLC Status is broken. It clears PLC shared object an extra files and force status to Empty. Added correponding Repair button to toolbar, visible only when PLC status is broken.
|
changeset |
files
|
Thu, 11 Apr 2019 13:45:27 +0200 |
Edouard Tisserant |
Background erase of debug variable panel was disabled for some reason, and it not anymore compatible with EVT_PAINT based refresh. It was leaving traces behind when removing traced variable. Fixed.
|
changeset |
files
|
Thu, 11 Apr 2019 13:41:52 +0200 |
Edouard Tisserant |
force redraw only through EVT_PAINT event and use wxPaintDC, as described in wx documentation
|
changeset |
files
|
Thu, 11 Apr 2019 11:26:47 +0200 |
Edouard Tisserant |
Fixed refresh problem following 9c5f835b031e, 9622418ac28c, c67488bd8134 : force redraw only through EVT_PAINT event and use wxPaintDC, as described in wx documentation
|
changeset |
files
|
Thu, 11 Apr 2019 08:40:17 +0200 |
Edouard Tisserant |
merged
|
changeset |
files
|