Tue, 24 Sep 2019 11:55:59 +0200 |
Edouard Tisserant |
Fixed unitialized parameter in instances_path stylesheet, leading to
|
changeset |
files
|
Sun, 14 Jul 2019 08:43:12 +0200 |
Edouard Tisserant |
Fixed code quality according to pep8 and pylint.
|
changeset |
files
|
Sat, 13 Jul 2019 10:57:25 +0200 |
Edouard Tisserant |
Fix exception on exit in some case, sequel of an earlier cleanup commit I couldn't find back. Disconnecting the event is apparently the way to go. https://wiki.wxpython.org/Surviving%20with%20wxEVT%20KILL%20FOCUS%20under%20Microsoft%20Windows
|
changeset |
files
|
Fri, 12 Jul 2019 11:53:04 +0200 |
Edouard Tisserant |
PurgeBlobs was faulty, but it was never having anything to purge. Fixed.
|
changeset |
files
|
Fri, 12 Jul 2019 11:51:47 +0200 |
Edouard Tisserant |
Fixed repetitive freezing of IDE when connection drops.
|
changeset |
files
|
Wed, 10 Jul 2019 11:21:13 +0200 |
Edouard Tisserant |
Better error handling when blob transfer fail
|
changeset |
files
|
Wed, 10 Jul 2019 10:43:14 +0200 |
Edouard Tisserant |
Removed dead code.
|
changeset |
files
|
Tue, 09 Jul 2019 09:49:30 +0200 |
Edouard Tisserant |
Now expects 1 more columns in VARIABLE.CSV file generated by MatIEC. Pair with MatIEC commit 9cb7c8bf7dbc :
|
changeset |
files
|
Tue, 18 Jun 2019 14:09:23 +0200 |
Edouard Tisserant |
Merged workaround for loading bug happening after automatic resize of function blocks. It appears that some code in GraphicCommons.py loop endlessly when wires coordinate do not align with x or y axis. Those erroneous coordinate are now filtered out when loaded in the view.
|
changeset |
files
|
Tue, 18 Jun 2019 14:03:08 +0200 |
Edouard Tisserant |
Removed debug code and closed branch
fix_fb_resize_wire_bug
|
changeset |
files
|
Tue, 18 Jun 2019 13:58:45 +0200 |
Edouard Tisserant |
GraphicCommons.py : Wire.SetPoints() move filtering before computation of Start and End points to avoid setting them with arbitrary directions.
fix_fb_resize_wire_bug
|
changeset |
files
|
Tue, 18 Jun 2019 09:38:20 +0200 |
Edouard Tisserant |
GraphicCommons.py : rewrote Wire.Setpoints.
fix_fb_resize_wire_bug
|
changeset |
files
|
Thu, 13 Jun 2019 15:49:48 +0200 |
Edouard Tisserant |
'Change POU Type To' becomes 'Duplicate as...', avoiding side effects of type change when POU is already instanciated. Also remove leftover returType tag in ex-function POUs, triggering exceptions at build time.
|
changeset |
files
|
Thu, 06 Jun 2019 14:03:16 +0200 |
Edouard Tisserant |
Fix PLCObject's purge failing silently with extra_files.
|
changeset |
files
|
Thu, 30 May 2019 11:53:13 +0200 |
Edouard Tisserant |
LogMessage shouldn't be serialized (can lead to blocking in case of exception in main thread), and do not require it.
|
changeset |
files
|
Thu, 30 May 2019 11:51:56 +0200 |
Edouard Tisserant |
Fixed typo leading to some exception in some rare corner cases in worker.py
|
changeset |
files
|
Tue, 23 Apr 2019 11:01:35 +0200 |
Edouard Tisserant |
Added missing 'path' field to WAMP addresses in URI editor.
|
changeset |
files
|
Tue, 23 Apr 2019 11:00:37 +0200 |
Edouard Tisserant |
Fixed exception when using URI editor for PYRO addresses
|
changeset |
files
|
Fri, 19 Apr 2019 13:11:42 +0200 |
Edouard Tisserant |
Avoid loading PLC at startup when autostart is not set in command line. As a side effect PLC status is artificially set to Stopped, and StartPLC eventually loads PLC if it is not already loaded.
|
changeset |
files
|
Fri, 19 Apr 2019 10:53:02 +0200 |
Edouard Tisserant |
Add Repair() to WAMP interface
|
changeset |
files
|
Thu, 18 Apr 2019 14:42:23 +0200 |
Edouard Tisserant |
Merged fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:41:21 +0200 |
Edouard Tisserant |
Close fix_PLC_runtime_shutdown
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:35:42 +0200 |
Edouard Tisserant |
Runtime worker : unblock the last waiting job and prevent any new job to wait when Main Worker is being shut down.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:34:22 +0200 |
Edouard Tisserant |
Add some "pipe to self" trick in Pyro server to accelerate runtime shutdown instead of waiting for arbitrary pyro timeout.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:32:43 +0200 |
Edouard Tisserant |
If call to GetPLCstatus can't be executed in PLC, then obtained status is disconnected. Status on "None" is not relevant anymore, and is replaced by Disconnected.
fix_PLC_runtime_shutdown
|
changeset |
files
|
Thu, 18 Apr 2019 14:29:55 +0200 |
Edouard Tisserant |
Enure that all threads are joined before trying to exit
fix_PLC_runtime_shutdown
|
changeset |
files
|
Wed, 17 Apr 2019 14:18:22 +0200 |
Edouard Tisserant |
Named runtime's threads to ease debugging
|
changeset |
files
|
Wed, 17 Apr 2019 14:15:39 +0200 |
Edouard Tisserant |
Added Repair() png icon
|
changeset |
files
|