Edouard Tisserant [Mon, 29 Jun 2020 14:38:04 +0200] rev 2685
Modbus: fix strange side effect of re-use of condition variables or mutex with Xenomai : without bzero of the associated types, mutex keeps locked.
Edouard Tisserant [Wed, 24 Jun 2020 14:38:11 +0200] rev 2684
Modbus: fix client timer invalid arguments.
Edouard Tisserant [Tue, 23 Jun 2020 13:50:21 +0200] rev 2683
Modbus add a timer thread, and switch timer to SIGEV_THREAD_ID to follow xenomai posix skin restrictions.
Edouard Tisserant [Fri, 19 Jun 2020 11:07:25 +0200] rev 2682
Runtime: Fix typo in PLCObject leading to exception when reporting failure.
Edouard Tisserant [Thu, 18 Jun 2020 14:18:16 +0200] rev 2681
Py_ext: use non-derived type when generating C code for handling Python PLC globals.
Edouard Tisserant [Wed, 17 Jun 2020 14:32:55 +0200] rev 2680
tests/python : add some STRING PLC Python globals with OnChange.
Edouard Tisserant [Wed, 17 Jun 2020 14:30:55 +0200] rev 2679
Runtime: STRING type for Python PLC Globals was making problem with strings, since generated code wasn't doing comparison properly.
Tomaz Orac [Tue, 16 Jun 2020 15:53:52 +0200] rev 2678
Merge
Edouard Tisserant [Tue, 16 Jun 2020 11:12:36 +0200] rev 2677
Modbus: more comments to remember some necessary changes.
Edouard Tisserant [Tue, 16 Jun 2020 10:16:25 +0200] rev 2676
Modbus/BACnet : add some comments so that we don't forget some pending optimization.
Edouard Tisserant [Tue, 16 Jun 2020 10:12:21 +0200] rev 2675
Modbus: Delete stored configuration when identical to default configuration.
Edouard Tisserant [Mon, 15 Jun 2020 14:34:00 +0200] rev 2674
BACnet: prevent saving configuration that is same as default, delete it if so.
Edouard Tisserant [Mon, 15 Jun 2020 14:29:41 +0200] rev 2673
BACnet and Modbus : fix configuration storage directory
Edouard Tisserant [Mon, 15 Jun 2020 14:27:58 +0200] rev 2672
Runtime extrension web settings: distinguish display string and token when calling NS.newExtensionSetting, thus allowing meaningful name to be displayed instead of an id.