Tue, 25 May 2021 15:05:38 +0200Runtime: Fix exception "Worker is disabled" when connecting while PLC runtime is starting. svghmi
Edouard Tisserant [Tue, 25 May 2021 15:05:38 +0200] rev 3248
Runtime: Fix exception "Worker is disabled" when connecting while PLC runtime is starting.

Pyro/wamp/UI delegate jobs to Worker, causing race condition if worker isn't already started.
Added a function to ensure that Worker is already created when pyro or UI starts

Mon, 31 May 2021 10:08:02 +0200SVGHMI: UI now have multiple HMI tree variables DnD to widget paths. Still no type checking, WIP. svghmi
Edouard Tisserant <edouard.tisserant@gmail.com> [Mon, 31 May 2021 10:08:02 +0200] rev 3247
SVGHMI: UI now have multiple HMI tree variables DnD to widget paths. Still no type checking, WIP.

Mon, 24 May 2021 14:33:54 +0200Finished fixing Wx IDs abuse. There was still some wasted IDs because of wx.NewId calls in many places where it wasn't needed, and those IDs were not re-used. As a consequence Beremiz was making exception crashing after a few hours of intensive use. svghmi
Edouard Tisserant [Mon, 24 May 2021 14:33:54 +0200] rev 3246
Finished fixing Wx IDs abuse. There was still some wasted IDs because of wx.NewId calls in many places where it wasn't needed, and those IDs were not re-used. As a consequence Beremiz was making exception crashing after a few hours of intensive use.