Edouard Tisserant [Wed, 15 Dec 2021 11:56:34 +0100] rev 3396
Runtime: Now retain uses a list based on data available in VARIABLES.csv instead of traversing the whole instance tree looking for RETAIN flag.
Edouard Tisserant [Thu, 09 Dec 2021 10:21:45 +0100] rev 3395
RUNTIME: Variable forcing now uses limited list and buffer instead of systematical instance tree traversal and in-tree "fvalue" to keep track of forced value for pointed variables (external, located). Pointer swapping is performed when forcing externals and located, with backup being restored when forcing is reset. Retain still uses tree traversal.
Edouard Tisserant [Wed, 01 Dec 2021 09:54:02 +0100] rev 3394
RUNTIME: Variable trace now uses limited list and buffer instead of flags in instance tree that was requiring systematical instance tree traversal, and worst size buffer. Forcing and retain still use tree traversal.
Edouard Tisserant [Tue, 30 Nov 2021 09:52:42 +0100] rev 3393
SVGHMI: more accurate filtering of elements to unlink or not
Edouard Tisserant <edouard.tisserant@gmail.com> [Tue, 30 Nov 2021 18:43:10 +0100] rev 3392
OPC-UA client: generated code now take UA_Variants on the stack directly, avoid useless allocation on write, and unalloc implicitely allocated data on read
Edouard Tisserant <edouard.tisserant@gmail.com> [Tue, 30 Nov 2021 18:43:10 +0100] rev 3391
OPC-UA client: generated code now take UA_Variants on the stack directly, avoid useless allocation on write, and unalloc implicitely allocated data on read
Edouard Tisserant <edouard.tisserant@gmail.com> [Tue, 16 Nov 2021 20:31:11 +0100] rev 3390
IDE: Tutorial/Example menu was broken : path of project being open was the same for all menu entries.
Edouard Tisserant <edouard.tisserant@gmail.com> [Wed, 17 Nov 2021 09:20:16 +0100] rev 3389
IDE: Tutorial/Example menu was broken, probably after a merge. Menu (and corresponding code) was duplicated. Also, path of project beeing open was the same for all menu entries.
Edouard Tisserant <edouard.tisserant@gmail.com> [Tue, 16 Nov 2021 20:10:50 +0100] rev 3388
Fix bug when updating data in variable panel.
Grid event naming CHANGE->CHANGING was wrong. CHANGE->CHANGED is the way to go.
Edouard Tisserant [Mon, 08 Nov 2021 14:10:36 +0100] rev 3387
SVGHMI: update tests/evghmi to reflect/test latest changes. update generated XSLT.
Edouard Tisserant [Mon, 08 Nov 2021 14:09:44 +0100] rev 3386
SVGHMI: multiple non significant changes: doc fixes, modern style access to attributes, enforce double quotes around member name in object literals.
Edouard Tisserant [Mon, 08 Nov 2021 14:06:29 +0100] rev 3385
SVGHMI: Changes /CURRENT_PAGE_* behaviour to prevent problem whith multiclient : all clients were switching page when one was jumping.
- now PLC have to prefix page name with "!" to order page switch.
- HMI do not prefix with "!" when jumping, this avoiding looping incidently
- In case of multiple client:
CURRENT_PAGE reflects current page of last client hwo did jump
Setting CURRENT_PAGE with "!" affects all clients simultaneously