Edouard Tisserant [Thu, 10 Dec 2020 15:48:15 +0100] rev 2699
Add a little test to see OnChange's .count .first .last in action
Edouard Tisserant [Thu, 10 Dec 2020 14:54:42 +0100] rev 2698
Fixed "Onchange" object added in previous commit
Edouard Tisserant <edouard.tisserant@gmail.com> [Thu, 10 Dec 2020 11:37:27 +0100] rev 2697
Python Safe Globals now have more reliable triggering of OnChange call. Added "Onchange" object to accessible runtime variables that let user python code see count of changes and first and last values.
Edouard Tisserant <edouard.tisserant@gmail.com> [Fri, 20 Nov 2020 11:17:40 +0100] rev 2696
Project tree: avoid flickering and glitches in notebook when selecting some still not opened ConfigTreeNode
Edouard Tisserant <edouard.tisserant@gmail.com> [Wed, 18 Nov 2020 23:06:16 +0100] rev 2695
Project tree: Clicking on ConfigTreeNode should have same behaviour as for POUS and other IEC types : simple click to select and double click to open.
Edouard Tisserant [Wed, 18 Nov 2020 10:15:44 +0100] rev 2694
py_ext: better handling of coma separated OnChange attribute for python safe global variables.
Edouard Tisserant <edouard.tisserant@gmail.com> [Mon, 02 Nov 2020 10:56:09 +0100] rev 2693
Allow customization of generated py_ext OnChange calls, by adding a static method to PythonFileCTNMixin that can the be later hot patched.
Edouard Tisserant <edouard.tisserant@gmail.com> [Tue, 20 Oct 2020 00:23:52 +0200] rev 2692
PY_EXT: OnChange is now a coma separated list of callables. Updated tests/python accordingly.
Edouard Tisserant [Tue, 15 Sep 2020 13:57:06 +0200] rev 2691
Modbus: fixed typo in ctype typing.
Edouard Tisserant [Fri, 11 Sep 2020 13:46:41 +0200] rev 2690
MODBUS: Fix saving of websettings.
Edouard Tisserant [Thu, 10 Sep 2020 16:08:26 +0200] rev 2689
Runtime/PLCObject : move call to PreStartPLC right after call to the "start" method of all python extensions, and then just before the start of the python loop executing python_* blocks.
Mario de Sousa <msousa@fe.up.pt> [Thu, 13 Aug 2020 19:00:38 +0100] rev 2688
Modbus plugin: reformat code, and add comment.
Mario de Sousa <msousa@fe.up.pt> [Thu, 13 Aug 2020 18:42:02 +0100] rev 2687
Modbus plugin: fix runtime periodic timer (don't use POSIX timer)
Edouard Tisserant [Wed, 01 Jul 2020 10:36:20 +0200] rev 2686
Modbus and Bacnet websettings : Rename variables and functions to avoid name collisions.
Websettings for modbus and bacnet are now passed to runtime as python files loaded (execfile) at init of PLCObject with the same globals.
Because if this, same names used in previously different modules now colide.
Edouard Tisserant [Mon, 29 Jun 2020 14:38:04 +0200] rev 2685
Modbus: fix strange side effect of re-use of condition variables or mutex with Xenomai : without bzero of the associated types, mutex keeps locked.
Edouard Tisserant [Wed, 24 Jun 2020 14:38:11 +0200] rev 2684
Modbus: fix client timer invalid arguments.
Edouard Tisserant [Tue, 23 Jun 2020 13:50:21 +0200] rev 2683
Modbus add a timer thread, and switch timer to SIGEV_THREAD_ID to follow xenomai posix skin restrictions.
Edouard Tisserant [Fri, 19 Jun 2020 11:07:25 +0200] rev 2682
Runtime: Fix typo in PLCObject leading to exception when reporting failure.
Edouard Tisserant [Thu, 18 Jun 2020 14:18:16 +0200] rev 2681
Py_ext: use non-derived type when generating C code for handling Python PLC globals.
Edouard Tisserant [Wed, 17 Jun 2020 14:32:55 +0200] rev 2680
tests/python : add some STRING PLC Python globals with OnChange.
Edouard Tisserant [Wed, 17 Jun 2020 14:30:55 +0200] rev 2679
Runtime: STRING type for Python PLC Globals was making problem with strings, since generated code wasn't doing comparison properly.
Tomaz Orac [Tue, 16 Jun 2020 15:53:52 +0200] rev 2678
Merge
Edouard Tisserant [Tue, 16 Jun 2020 11:12:36 +0200] rev 2677
Modbus: more comments to remember some necessary changes.
Edouard Tisserant [Tue, 16 Jun 2020 10:16:25 +0200] rev 2676
Modbus/BACnet : add some comments so that we don't forget some pending optimization.
Edouard Tisserant [Tue, 16 Jun 2020 10:12:21 +0200] rev 2675
Modbus: Delete stored configuration when identical to default configuration.
Edouard Tisserant [Mon, 15 Jun 2020 14:34:00 +0200] rev 2674
BACnet: prevent saving configuration that is same as default, delete it if so.
Edouard Tisserant [Mon, 15 Jun 2020 14:29:41 +0200] rev 2673
BACnet and Modbus : fix configuration storage directory
Edouard Tisserant [Mon, 15 Jun 2020 14:27:58 +0200] rev 2672
Runtime extrension web settings: distinguish display string and token when calling NS.newExtensionSetting, thus allowing meaningful name to be displayed instead of an id.
Edouard Tisserant [Fri, 12 Jun 2020 14:40:50 +0200] rev 2671
Debug : when BEREMIZ_DEBUG file exist, display all commands issued in console.
Edouard Tisserant [Fri, 12 Jun 2020 14:39:32 +0200] rev 2670
BACnet and Modbus : Simpler configuration management. NevowServer.py now allows each extension to create and delete multiple configuration forms in the setting page, deprecating delSettings and addAfter.
Edouard Tisserant [Fri, 12 Jun 2020 10:30:23 +0200] rev 2669
BACnet and Modbus: Remove additional loading and unloading, use the one already in place for extensions.
Mario de Sousa <msousa@fe.up.pt> [Sun, 07 Jun 2020 23:47:32 +0100] rev 2668
merge
Mario de Sousa <msousa@fe.up.pt> [Sun, 07 Jun 2020 23:46:16 +0100] rev 2667
Bacnet plugin web configuration: strip leading and trailing spaces for net. interface and port numb.
Mario de Sousa <msousa@fe.up.pt> [Sun, 07 Jun 2020 23:38:20 +0100] rev 2666
Modbus plugin, web interface: strip leading and trailing spaces from string parameters
Mario de Sousa <msousa@fe.up.pt> [Sun, 07 Jun 2020 22:32:24 +0100] rev 2665
Modbus plugin web interface: show the keyword "#ANY#" on TCP servers
Mario de Sousa <msousa@fe.up.pt> [Sun, 07 Jun 2020 19:33:32 +0100] rev 2664
Modbus plugin: fix bug: was checking user configuration against wrong limits
Mario de Sousa <msousa@fe.up.pt> [Sun, 07 Jun 2020 18:34:32 +0100] rev 2663
Modbus plugin: fix algorithm detecting Modbus TCP servers using the same IP port on the same network interface
Mario de Sousa <msousa@fe.up.pt> [Sun, 07 Jun 2020 12:28:21 +0100] rev 2662
Modbus plugin: check for duplicate "Configuration_Name"
Mario de Sousa <msousa@fe.up.pt> [Sat, 06 Jun 2020 08:51:32 +0100] rev 2661
add comment
Mario de Sousa <msousa@fe.up.pt> [Sat, 06 Jun 2020 08:50:36 +0100] rev 2660
add comment
Mario de Sousa <msousa@fe.up.pt> [Sat, 06 Jun 2020 08:43:41 +0100] rev 2659
merge
Mario de Sousa <msousa@fe.up.pt> [Sat, 06 Jun 2020 07:34:02 +0100] rev 2658
Modbus plugin web configuration: fix comments, and delete un-used code
Mario de Sousa <msousa@fe.up.pt> [Sat, 06 Jun 2020 07:24:42 +0100] rev 2657
Modbus plugin web configuration: use drop down choices for baud, parity and stop bits.
Mario de Sousa <msousa@fe.up.pt> [Fri, 05 Jun 2020 18:02:12 +0100] rev 2656
Modbus plugin web configuration: save node type and addr type to persistant storage
Mario de Sousa <msousa@fe.up.pt> [Mon, 01 Jun 2020 14:11:22 +0100] rev 2655
Add web extension: configure Modbus Server plugin parameters
Mario de Sousa <msousa@fe.up.pt> [Mon, 01 Jun 2020 08:54:26 +0100] rev 2654
Add web extension: configure Modbus plugin parameters (currently only supports Modbus clients)
Edouard Tisserant [Tue, 02 Jun 2020 13:37:34 +0200] rev 2653
Runtime: create .md5 file at the end of all transfered files being written to disk, so that it presence indicates completeness of transfer.
Edouard Tisserant [Tue, 02 Jun 2020 11:34:50 +0200] rev 2652
IDE: Main toolbar : Show repair button also in stop mode. Move repair button after disconnect button.
Edouard Tisserant [Mon, 01 Jun 2020 14:47:31 +0200] rev 2651
Runtime: fsync() files when transfering them, to prebent data loss when poweroff soon after programming. Fixed variable naming as a side effect.
Mario de Sousa <msousa@fe.up.pt> [Thu, 28 May 2020 11:16:59 +0100] rev 2650
merge
Mario de Sousa <msousa@fe.up.pt> [Thu, 28 May 2020 11:15:22 +0100] rev 2649
BACnet plugin: Add web interface for online parameter configuration
Mario de Sousa <msousa@fe.up.pt> [Thu, 28 May 2020 11:01:42 +0100] rev 2648
modbus_plugin: generate nicer error message, instead of a traceback
Mario de Sousa <msousa@fe.up.pt> [Thu, 28 May 2020 10:54:48 +0100] rev 2647
Modbus plugin: Add "exec. req. flag" and "write on change" features
Edouard Tisserant [Thu, 28 May 2020 11:38:09 +0200] rev 2646
PLCObject : reorganize code in StartPLC(), add a PreStartPLC() empty method, to be overloaded by runtime extensions.
Edouard Tisserant [Tue, 26 May 2020 09:58:20 +0200] rev 2645
Solve import order problem when POULibrary imports ConfigTreeNode because of UserAddressedException. Now UserAddressedException is declared in POULibrary.py, as a quick and dirty fix, but some independant module should be created for beremiz exceptions in general.
Edouard Tisserant [Wed, 18 Dec 2019 13:31:22 +0100] rev 2644
Add --on-plc-start --on-plc-stop and --status-change to runtime command line, calling given command respectively on start stop or any event. Command line string is python formated (to eventually include status with {}) before being split (supports quoted strings) and passed to Popen for non-blocking execution.
Edouard Tisserant <edouard.tisserant@gmail.com> [Mon, 25 Nov 2019 08:10:45 +0100] rev 2643
Etherlab : Merged 2014-2018 changes from jblee and others
Edouard Tisserant <edouard.tisserant@gmail.com> [Mon, 25 Nov 2019 08:26:55 +0100] rev 2642
Close branch ethercat_from_kosmos
Edouard Tisserant <edouard.tisserant@gmail.com> [Wed, 20 Nov 2019 16:57:15 +0100] rev 2641
EtherCat master plugin : commit changes recovered from KOSMOS 2018 installer, unkown author(s).
Edouard Tisserant [Wed, 13 Nov 2019 11:21:04 +0100] rev 2640
Add FatalError() method to ConfigTreeNode.
Extensions can report error addressed to user, without a traceback.