Edouard Tisserant [Thu, 10 May 2018 08:33:50 +0200] rev 2004
Allow deleting configuration tree node with no corresponding directory in project tree
Edouard Tisserant [Mon, 07 May 2018 15:10:39 +0200] rev 2003
Support unicode in LDFLAGS returned by extensions
Edouard Tisserant [Mon, 07 May 2018 14:19:08 +0200] rev 2002
Fixed typos
dporopat <denis.poropat@smarteh.si> [Fri, 20 Apr 2018 11:21:20 +0200] rev 2001
#2476 Added uri location editor, getting connectors from list in Beremiz.
Edouard Tisserant [Fri, 27 Apr 2018 16:32:53 +0200] rev 2000
Fixed random segfault happening when loading new PLC in runtime, when using Xenonai.
Edouard Tisserant [Thu, 19 Apr 2018 15:17:05 +0200] rev 1999
PEP-8 and PyLint
Edouard Tisserant [Thu, 19 Apr 2018 15:03:23 +0200] rev 1998
merged Denis change to apply input as we type in CTN configuration forms text fieds
Edouard Tisserant [Thu, 19 Apr 2018 14:53:42 +0200] rev 1997
PEP-8 and PyLint
Edouard Tisserant [Thu, 19 Apr 2018 13:09:41 +0200] rev 1996
Add safety check to prevent exception when disconnecting while debugging
Edouard Tisserant [Thu, 19 Apr 2018 13:02:13 +0200] rev 1995
Removed DebugThread. Take advantage of the fact that buffering is done in runtime. No need to poll for traces more than ten per second, then use simple wxTimer for that. Also removed Debug Lock since now everything happens in wx' mainloop.
Edouard Tisserant [Thu, 19 Apr 2018 12:22:40 +0200] rev 1994
Rework of runtime non-real-time threading, and shared object dynamic loading :
- All exposed operations on PLCObject are now serialized through main thread
(@RunInMain). Only one exception : python trace thread calling _GetDebugData
- Re-loading of same shared object is prevented. dlclose/delte/rewrite/dlopen
don't happen in that case. This is a workaround for some xenomai copperplate
bug triggering segfault, inbetween delete and rewrite.
- Trace thread now waits for data, dies if no data, and dies instead of
suspending as before when no data consumed after 3 seconds.
- Disabled threading in Pyro client
- Enforced auxiliary threads starting sequence : Pyro -> [UI] ->
PLCWorker.RunLoop
Edouard Tisserant [Tue, 17 Apr 2018 11:19:18 +0200] rev 1993
Stripped forgotten debug code
Edouard Tisserant <edouard.tisserant@gmail.com> [Thu, 19 Apr 2018 15:06:10 +0200] rev 1992
close branch
dporopat <denis.poropat@smarteh.si> [Thu, 19 Apr 2018 09:50:00 +0200] rev 1991
#2476 Fix for saving text in URI edit text box. No need to click out of URI edit text box to save edited text.